![Jets 121315143 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/jets/121315143/121315143_manual_646323004.webp)
VAC Controller CVS/VIP
Tel. +47 70 03 91 00
www.jetsgroup.com
Product No. 121315143
Doc. Rev.: 5 (2020-11-30)
4
Installation
Prior to Installation
Before starting any work on the VAC Controller, ensure that the power has been disconnected.
3.2 Warning
Never work on the equipment when mains power is applied.
For equipment fitted with a frequency converter: After disconnecting the input power, always wait for 5 min to let the intermediate circuit capacitors discharge before you start
working on the equipment.
3.1 Warning
All wiring should be performed by a licensed or certified electrician.
Prior to installing the VAC Controller, read all technical information in this document. The document contains important information related to the
installation and settings for your installation.
Electrical Connections Diagram
A - Pre-wired
B - Signal cable to the Vacuumarator™ pump
C - Vacuum transmitter
D - VIP signal (optional)
E - Tank level (optional)
F - Alarm - Power on (normally open contact)
G - Alarm - Low vacuum
H - Alarm - Full tank
I - Alarm - Long running time
J - Optional power supply
K - Power supply
L - Presence detectors (max 10 sensors)
M - Grey water tank level switch connections (max 5 grey water
tanks)
Power Supply
● J - Optional 12/24VDC Power Supply
Optional power output or VIP sensor power supply, if needed.
● K - Power Supply
The power supply includes an EU plug adapter. If needed, US, UK and AUS plug adapters are also available.