![Jets 121315143 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/jets/121315143/121315143_manual_646323010.webp)
VAC Controller CVS/VIP
Tel. +47 70 03 91 00
www.jetsgroup.com
Product No. 121315143
Doc. Rev.: 5 (2020-11-30)
10
● Vacuum setting 2.4
2.4.1 - Start vacuum level
Default: 30%
Pump start level: 30-50% vacuum
2.4.2 - Stop vacuum level
Default: 50%
Stop pump level: 40-70% vacuum
___________________________________________________________________________________________________________________
● VIP setting 2.5
Runtime after VIP signal (minutes)
Default: 5 minute delay active operation time (the
pump will hold the vacuum betwen set point in xx-
minutes) after activated sensor or level switch:
1-60 minutes.
___________________________________________________________________________________________________________________
● Operation data 2.6
2.6.1 - Date
Press OK and the value will
blink. Arrow up and down and
press OK to set the day,
month and year.
2.6.2 - Time
Press OK and the value will
blink. Arrow up and down and
press OK to set the hour and
minutes, using the 24-hour
clock.
2.6.3 - Running hours
Total count of pump running
time in hours.
This is a read out only and
cannot be reset.
2.6.4 - Total PowerUp count
A counter for the total time the
controller has been connected
to power.
This is a read out only and
cannot be reset.