Page 18
Function
: Permits the 9700W to pass a pulse signal to another device. This signal would be used if
it is desired to pulse a third party control. It is not used with Jetline 9600 series controlled
equipment. The signal from these pins directly follows the Pulse Lockout Input signal.
Electrical
: This is an open collector output, Pin K is high, Pin L is low.
AUX3 OUTPUT (Pins M & N)
Function
: When the “Arc On” signal has been received by the control, this contact closes, relaying
the signal to anther device to initiate its function. This contact opens during the stop sequence.
Electrical
: We supply a dry relay contact capable of handling 110VAC at 0.6A.
S2 CONNECTOR
The S2 connector is used to connect the 9700W wire feed control to a 9700T travel control. In
certain circumstances, it can be interfaced with a PLC or other control interface. Jetline can provide
standard connecting cables to be connected to the S2 connector on the 9700W control. If you need
to provide your own cable, it should be fitted with the following:
Amphenol plug
97-3106A-20-27P
Cord Grip
97-3057-1012-1
Pin Connection Details
Connections should be made as shown below.
REMOTE START INPUT (Pins A & B)
Function
: When this circuit is completed, the 9700W control will start the programmed sequence.
The process will continue until this contact is removed.
Electrical
: You can connect a dry relay contact or an open collector signal, Pin A is high, Pin B is
low. Either one must handle 12VDC at 4mA.
EMERGENCY STOP INPUT (Pins C & D)
Function
: When this circuit is opened, the 9700W control will initiate an emergency stop sequence.
Electrical
: You can connect a dry relay contact or an open collector signal, Pin C is high, Pin D is
low. Either one must handle 12VDC at 4mA. Logic must be normally closed.
PULSE LOCKOUT INPUT (Pins E & F)
Function
: When the control is connected to a power supply with pulse current facilities, it is
sometimes necessary to the wire feed with the current pulsing. When the control is connected to the
current background signal through these connections the wire can pulse with the arc.
Electrical
: You can connect a dry relay contact or an open collector signal, Pin E is high, Pin F is
low. Either one must handle 12VDC at 4mA.
AUX1 OUTPUT (Pins G & H)
Function
: When the “Arc On” signal has been received by the control, this contact closes, relaying
the signal to anther device to initiate its function. This contact opens during the stop sequence.
Electrical
: We supply a dry relay contact capable of handling 110VAC at 0.6A.