9629 Microprocessor Controller
- 7 -
Section I.
Safety Precautions
WARNING
CALIFORNIA PROPOSITION 65 WARNING
This product contains chemicals, including lead,
known to the state of California to cause cancer,
and birth defects or other reproductive harm.
Wash hands after use. §248224
A. Arc Welding
Arc Welding can be hazardous.
Protect your-
self and others from possible serious injury or
death. Keep children away. Pacemaker wear-
ers keep away until consulting your doctor.
In welding, as in most jobs, exposure to certain
hazards occurs. Welding is safe when precau-
tions are taken. The safety information given
below is only a summary of the more complete
safety information that will be found in the
Safety Standards listed at the end of this section.
Read and follow all Safety Standards.
Have all installation, operation, maintenance
and repair work performed only by qualified
people.
B. Electric Shock
Touching live electrical parts can cause fatal
shocks or severe burns. The electrode and work
circuit is electrically live whenever the output is
on. The input power circuit and machine internal
circuits are also live when power is on. When
using mechanized wire feed, the wire, wire reel,
drive roll housing and all metal parts touching
the welding wire are electrically live. Incorrectly
installed or improperly grounded equipment is
a hazard.
1.
Do not touch live electrical parts.
2.
Wear dry, hole-free insulating gloves and
appropriate body protection.
3.
Disconnect input power before installing
or servicing this equipment. Lockout/ta-
gout input power according to OSHA 29
CFR 1910.147 (see Safety Standards).
4.
Properly install and ground this equipment
according to the operation manual and
national, state and local codes.
5.
Always verify the supply ground-check
and be sure that input power cord ground
wire is properly connected to ground
terminal in disconnect box or that cord
plug is connected to a properly grounded
receptacle outlet.
6.
When making input connections, attach
proper grounding conductor first - double-
check connections.
7.
Frequently inspect input power cord for
damage or bare wiring. Replace cord im-
mediately if damaged - bare wiring can
kill.
8.
Turn off all equipment when not in use.
9.
If earth grounding of the workpiece is required,
ground it directly with a separate cable - do not
use work clamp or work cable.
10.
Do not touch electrode if you are in con-
tact with the work, ground, or another
electrode from a different machine.
11.
Use only well-maintained equipment.
Repair or replace damaged parts at once.
Maintain unit according to manual.
12. Wear a safety harness if working above
floor level.
13.
Keep all panels and covers securely in
place.
14.
Clamp work cable with good metal-to-
metal contact to workpiece or worktable
as near the weld as practical.
Содержание 9600 Series
Страница 2: ...9629 Microprocessor Controller 2...
Страница 6: ...9629 Microprocessor Controller 6...
Страница 41: ...9629 Microprocessor Controller 41 Figure 1 Enclosure SUB PANEL GROUND MAIN GROUND...
Страница 43: ...9629 Microprocessor Controller 43 Figure 2 Enclosure Door...
Страница 49: ...9629 Microprocessor Controller 49 S1 CONNECTOR...
Страница 50: ...9629 Microprocessor Controller 50 S2 CONNECTOR...
Страница 51: ...9629 Microprocessor Controller 51 S3 CONNECTOR...
Страница 52: ...9629 Microprocessor Controller 52...
Страница 53: ...9629 Microprocessor Controller 53 Interconnection Diagram...