Instructions manual: MULi6s Module

1. Description:

The  MULi6s  Module  is  a sensor designed  to monitor the Li-XX battery voltage, which  measures  the
voltage  of each  battery cell  via  the balance  connector. It allows  you  to monitor the voltage of up  to
6 Li-XX cells  per module. The individual MULi6s modules  can be serialized and can be connected to

up to 5 modules.

 The MULi6s Module sensor monitors the voltage of each battery cell with its history

(minimum,  maximum),  the total battery voltage, the voltage  difference  between the strongest and  the
weakest cells, and the sensor is able to alert the operator to exceed the set parameters by means of alarms.
Sensor information is transmitted by the Duplex system to the operator.

The Duplex system uses  a 2.4GHz bandwidth to communicate, not only to the model,  but also  to the
transmitter. The telemetry data acquired during operation is transmitted in real time and the current state
of the measured quantities can be displayed on the JETIBOX LCD or DC / DS transmitters.

2. Sensor connection Muli6s Module:

Notice!

 Try to follow the following connection procedure:

1. 

Connect the MULi6s Module sensor to the Li-XX battery connector. 

    

(Make sure the connector polarity is correct!)

2. 

Connect the MULi6s Module sensor to the receiver / Expander via the JR connector

3. 

Connect the negative pole (-) of the battery to the controller / BEC

4.

Connect the positive pole (+) of the battery to the controller / BEC

Sensor   MULi6s   Module   connects   the   battery   module   to   the   battery   via   the   balance   connector.   The
balance connector must be wired as shown below. When the monitored battery is connected to the sensor,
identification of the number of cells  is started and, after 3 seconds, the sensor locks into the number of
cells detected. The sensor is always locked until it is switched off. Re-connecting the sensors to the power
supply   will   lead  to  a  new   identification  process.   If the  sensor  is   locked,  any   change  detected  in  the
number of connected cells will cause a fault. The fault is indicated by a red LED. The change can also be
detected by means of set alarms directly in the sensor via the Jetibox (see chapter Alarms) or the alarms
set in the DC / DS transmitter (see Chapter Configuration using the DC / DS transmitter).

3

Содержание MULi6s EX

Страница 1: ...INSTRUCTIONS FOR USING SENSOR MULI6S MODULE Producer JETI model s r o 14 12 2017...

Страница 2: ...6s Module SENSOR CONNECTION OPTION 6 3 1 Jetibox 6 3 2 Receiver 6 4 MENU JETIBOX 7 4 1 Actual values 7 4 2 Min Max 8 4 3 Settings 8 4 4 Alarms 8 4 5 Service 8 5 CONFIGURATION USING A DC DS TRANSMITTER...

Страница 3: ...sor connection Muli6s Module Notice Try to follow the following connection procedure 1 Connect the MULi6s Module sensor to the Li XX battery connector Make sure the connector polarity is correct 2 Con...

Страница 4: ...go out after a while Then the LED always lights for 0 3s and displays the state of the weakest cell to save the potential of the first two cells To put the module back into sleep mode just unplug the...

Страница 5: ...Instructions manual MULi6s Module Notice Only use wires that are part of the sensor for serial connection of modules 5...

Страница 6: ...s because the siren is part of a transmitter module that is not connected in this case Alarms are only displayed on the LCD 2 Connect the 3 wire MULi6s Module sensor cable with the JR connector to the...

Страница 7: ...ead data When connected to the MULi6s Module a startup screen appears which contains the sensor identification and the number of connected battery cells on the first row of the sensors of all connecte...

Страница 8: ...minimum and maximum will be reset when the sensor is switched on for the first time 4 4 MULi6s Module MENU ALARMS Press the D Down Arrow button to enter the individual alarm settings If a set paramet...

Страница 9: ...will go to the configuration menu Reset to factory defaults to retrieve the default MULi6s Module setting 5 1 Telemetry Total voltage shows the current total battery voltage and the number of all con...

Страница 10: ...kest and strongest cells throughout the flight In addition to the voltage which of the two cells this difference affects the first number corresponds to the strongest cell MIN MAX Telemetry of all cel...

Страница 11: ...Consumption 70uA Maximum of connected modules 5 Number of batteries connected to one module 1 Maximum number of cells connected to one module 6 Maximum voltage on one module 26 4V 8 Guarantee The prod...

Страница 12: ...Instructions manual MULi6s Module MULi6s Module menu displayed on JETIBOX terminal 12...