Instructions manual: MULi6s Module
Notice!
The module that connects to the powered receiver is automatically set as Master. Otherwise, it
has Slave status. For the proper operation of the module as a Master, the power supply to the connected
receiver must also be connected for the first time after connecting the battery. If the battery and receiver
power are disconnected, the process described above will have to be performed after reconnecting the
battery. While the receiver is connected to the sensor while the receiver is switched off and the module is
not yet identified as Master, the battery module removes a higher current of approximately 0.5mA. After
identifying and disconnecting the receiver's power, this current is 70uA, see chapter Technical data.
The same procedure as the receiver applies to Jetibox and other connected devices on the EXT output of
the MULi6s Module sensor. So if only the battery is connected to the sensor, the sensor is set to Slave and
takes the type 70uA. If the receiver is connected to the sensor in addition to the battery or the Jetibox, the
sensor will take 0.5mA until the power supply of the receiver or Jetibox is connected, then after
disconnecting the receiver power, the sensor behaves like a 70uA Master.
Slave is always powered by his first two cells.
4. Menu JETIBOX:
The JETIBOX terminal (or Device Explorer in the Jeti DC / DS transmitter) is used to set parameters and
read data. When connected to the MULi6s Module, a startup screen appears, which contains the sensor
identification and the number of connected battery cells on the first row of the sensors of all connected
modules. The second line shows the lowest voltage from the connected cells and the total battery voltage.
When the power supply is connected to the sensor via EXT, the "initialization" message is displayed for a
short time on this line, when all the articles are read, after which the inscription disappears.
Pressing R (right) for 2 seconds will cause the Min / Max value to be cleared. Press the D (down)
button on the JETIBOX to enter the MULi6s Module sensor menu.
4.1.
MULi6s Module MENU mode: ACT. VALUES
- Press D (down arrow) to select the current
measured values
Lowest voltage
- shows the current voltage of the lowest voltage cell of all connected cells and the
weakest cell number.
Highest voltage
- displays the current voltage of the highest voltage cell of all connected cells and the
number of the strongest cell.
Largest difference
- Displays the current voltage difference between the weakest and the strongest
cells. In addition to the voltage, it also shows the numbers of the cells between which this difference
is measured. The first number corresponds to the strongest article.
Total voltage
- shows the current total battery voltage and the number of all connected cells.
No. of modules
- displays the current number of connected modules.
Single cells
- Displays the current voltage of individual cells and their voltage difference from the
strongest cell. Use R and L to select the article number that we want to view.
7