Configuration using a DC / DS transmitter:

MULi6s Module can be configured via the DC / DS transmitter via the Connected Devices menu.     
In order to configure MULi6s via the transmitter, it is necessary to observe:

Firmware version of Duplex 3.12 and later (with Output mode setting -> EX bus).

Receiver connected to MULi6s Module with EX Bus.

Transmitter   firmware   version   2.02   and   later   +   device   profile   (MULi6M.bin)   recorded   in   the
"Devices" directory on the transmitter SD card.

If everything  is  properly  plugged  in,  or configured,  the  MULi6s  Module   entry appears  in  the
Connected Devices menu. Entering this item will go to the configuration menu.

Reset to factory defaults

 - to retrieve the default MULi6s Module setting.

5.1.

Telemetry 

Total voltage

 - shows the current total battery voltage and the number of all connected cells

Number of cells

 - shows the current number of connected cells

Number of modules

 - displays the current number of connected modules

The weakest link

 - displays the weakest link for the entire flight - its voltage and cell number

Largest difference

 - shows the current voltage difference between the weakest and the strongest

cell.   In   addition   to   the   voltage,   it   also   shows   the   numbers   of   the   cells   between   which   this
difference is measured. The first number corresponds to the strongest cell.

Telemetry of all cells

 - displays  all connected cells and their current voltage difference between

the weakest and the strongest cells.

9

Содержание MULi6s EX

Страница 1: ...INSTRUCTIONS FOR USING SENSOR MULI6S MODULE Producer JETI model s r o 14 12 2017...

Страница 2: ...6s Module SENSOR CONNECTION OPTION 6 3 1 Jetibox 6 3 2 Receiver 6 4 MENU JETIBOX 7 4 1 Actual values 7 4 2 Min Max 8 4 3 Settings 8 4 4 Alarms 8 4 5 Service 8 5 CONFIGURATION USING A DC DS TRANSMITTER...

Страница 3: ...sor connection Muli6s Module Notice Try to follow the following connection procedure 1 Connect the MULi6s Module sensor to the Li XX battery connector Make sure the connector polarity is correct 2 Con...

Страница 4: ...go out after a while Then the LED always lights for 0 3s and displays the state of the weakest cell to save the potential of the first two cells To put the module back into sleep mode just unplug the...

Страница 5: ...Instructions manual MULi6s Module Notice Only use wires that are part of the sensor for serial connection of modules 5...

Страница 6: ...s because the siren is part of a transmitter module that is not connected in this case Alarms are only displayed on the LCD 2 Connect the 3 wire MULi6s Module sensor cable with the JR connector to the...

Страница 7: ...ead data When connected to the MULi6s Module a startup screen appears which contains the sensor identification and the number of connected battery cells on the first row of the sensors of all connecte...

Страница 8: ...minimum and maximum will be reset when the sensor is switched on for the first time 4 4 MULi6s Module MENU ALARMS Press the D Down Arrow button to enter the individual alarm settings If a set paramet...

Страница 9: ...will go to the configuration menu Reset to factory defaults to retrieve the default MULi6s Module setting 5 1 Telemetry Total voltage shows the current total battery voltage and the number of all con...

Страница 10: ...kest and strongest cells throughout the flight In addition to the voltage which of the two cells this difference affects the first number corresponds to the strongest cell MIN MAX Telemetry of all cel...

Страница 11: ...Consumption 70uA Maximum of connected modules 5 Number of batteries connected to one module 1 Maximum number of cells connected to one module 6 Maximum voltage on one module 26 4V 8 Guarantee The prod...

Страница 12: ...Instructions manual MULi6s Module MULi6s Module menu displayed on JETIBOX terminal 12...

Отзывы: