13. WARRANTY INFORMATION 

JetBlack  Safety  is  a  trading  name  of  Air  Control  Industries  Ltd  (ACI).  Subject  to  the  restrictions  mentioned  below,  your 
equipment Warranty covers the repair or replacement, free of charge, of  parts acknowledged to be faulty by Air Control 
Industries Ltd (ACI), as well as the labour necessary to repair the equipment for twelve months from the date of shipment. 
 

Please Note That 

 

The Warranty is dependent upon the manufacturers recommended maintenance and servicing being carried 

out at the time intervals specified in this Manual. It may be necessary to provide proof of this (maintenance 
records, invoices etc). 

 

The motor within the Cleaning Station unit has a working life of 500 hours and the brushes may need 

replacing after this period. This is considered to be normal wear associated with the use of the motor and 
therefore not covered under the Warranty. Spares can be purchased from ACI. 

 

Work carried out under the Warranty does not extend the Warranty. In particular, the replacement of a part 

during work carried out under Warranty does not extend the lifespan of the part. The Warranty which covers 

the replacement part expires on the date of expiry of your equipment’s

 Warranty. 

 

Parts replaced under the Warranty become the property of ACI. 

 

At no time will ACI be liable for any of the costs to the buyer for labour, transportation or down-time resulting 

from defective equipment furnished by ACI or our suppliers. 

 

What The Warranty Does Not Cover 

 

Maintenance and servicing operations necessary for the correct operation of the equipment, mentioned in 

the Maintenance sections of this document. 

 

If the defect was due to accident or misuse, operation in an application not approved by ACI or an 

unauthorised modification or repair. 

 

Consumable parts and their routine replacement, such as filters etc. 

 

The replacement of parts that are subject to normal wear associated with use of the equipment, if this 

replacement is not the consequence of a fault. 

 

Damage caused by natural phenomena, hail, flooding, storms or other atmospheric hazards, as well as 

damage caused by accidents, fire or theft. 

Our products are manufactured in compliance with applicable international standards and regulations. If you have any 
queries regarding the use of our products, or if you are planning a special application, please contact ACI. 

 
14. WEEE RECYCLING & MATERIALS DISPOSAL 

https://www.aircontrolindustries.com/about-us/certificates-approvals/

 

 

 

Содержание SAFETY CLEANING BOOTH

Страница 1: ...TABLE OF CONTENTS ACM 0043 Issue 12...

Страница 2: ...IPMENT ARRIVAL INSPECTION 6 SAFETY INFORMATION 7 INSTALLATION PROCEDURES 8 GENERAL OPERATION 9 SYSTEM RATING 10 JETBLACK SAFETY CLEANING STATION INFORMATION 11 WIRING DIAGRAMS 12 LEV DATA 13 WARRANTY...

Страница 3: ...uggested in HSG258 a smoke test is not required Duct velocities should be checked at 1 The booth roof 2 The inlet of the duct to the extractor 3 The inlet to the extractor Base level velocities at the...

Страница 4: ...r Version Features Internal Features for both Internal and External models All weather painted steel enclosure Entry Exit door with viewing windows Makralon Extractor Unit Rain cover for main Booth en...

Страница 5: ...5 of 22 4 Cleaning Station Nozzle Assembly LED Light On Off Switch PIR Sensor Hose Foot Grille Emergency Stop Manufacturer LEV label Pressure Gauge PPE Label...

Страница 6: ...6 of 22 4 OUTLINE DRAWINGS Indoor Version Outdoor Version 5 EQUIPMENT ARRIVAL INSPECTION If there are any shortages discrepancies or damage to your product upon delivery please immediately contact the...

Страница 7: ...before connection It is recommended that the unit be hard wired to an electrical supply that is surge protected and in compliance with local codes Check the base Earth point located at the rear is in...

Страница 8: ...s is so an operator knows the booth is working correctly before they use the system 3 Unpack the consignment and position the main Booth assembly in place Remove 4x Black Transport brackets from the b...

Страница 9: ...main isolator if supplied The light and extractor will automatically start when either door is opened Inside the Booth safety information is located above the start button Please press the internally...

Страница 10: ...In this case stop using the Booth immediately isolate the supply check all ducting collection parts thoroughly The Booth will automatically switch off if the gauge pressure reads above 1 25kPa In this...

Страница 11: ...st cases 20 30 seconds is a sufficient cleaning cycle Do not worry about getting too close to the airflow of the Cleaning Station it is perfectly safe and will not cause any harm In fact the closer th...

Страница 12: ...C Limits for harmonic current emissions EN 61000 3 3 Limits of voltage changes fluctuations and flicker in public low voltage supply system Cleaning Station Maintenance and Service The following point...

Страница 13: ...se Replace damaged hose Air leaks in system Check replace damaged hose and clips Irregular Excessive Noise Blockage in air ducting Check all ducting and air delivery devices for blockages damage Repla...

Страница 14: ...14 of 22 11 WIRING DIAGRAMS...

Страница 15: ...15 of 22...

Страница 16: ...been installed it should be tested for LEV compliance if applicable The following test procedure will guide the LEV service provider into making a full true correct commissioning report 1 Ensure that...

Страница 17: ...e UK this product should be LEV tested commissioned The test required is based on exceeding airflow speeds suggested in HSG258 a smoke test is not required Duct velocities should be checked at 1 The b...

Страница 18: ...that THIS MUST ALWAYS READ ABOVE 5m s for safe operation with all items in place the doors closed 9m s is a good top level extraction airspeed m s Y This is applicable for nozzle only versions Does th...

Страница 19: ...on damage Check waste collectors damage condition Empty dust collection bags Comments 1 2 3 4 5 6 7 8 9 10 11 12 CHANGE RECIPROCATOR GUARD FILTERS 0 1257 10 PAPER ROOF FILTER BHTF01 ELEMENT 13 14 15 1...

Страница 20: ...36 CHANGE RECIPROCATOR GUARD FILTERS 0 1257 10 PAPER ROOF FILTER BHTF01 ELEMENT 37 38 39 40 41 42 43 44 45 46 47 48 CHANGE RECIPROCATOR GUARD FILTERS 0 1257 10 PAPER ROOF FILTER BHTF01 ELEMENT 49 50...

Страница 21: ...ich covers the replacement part expires on the date of expiry of your equipment s Warranty Parts replaced under the Warranty become the property of ACI At no time will ACI be liable for any of the cos...

Страница 22: ...ntrol Industries Ltd Weycroft Avenue Millwey Rise Industrial Estate Axminster EX13 5HU UK www aircontrolindustries com sales aircontrolindustries com Tel 44 0 1297 529242 Air Control Industries INC 76...

Отзывы: