DRO messages and fault codes (JWL-1840DVR only)
Table 3
Display Possible
Cause
Correction
RSET
Significant load spike due
to chisel dig-in; or fwd/rev
switch moved while in
education mode
To clear, turn off switch, wait for two “beeps”, then turn on
switch.
Refer to sect. 11.3 to analyze motor load.
Alarm code
Message
Explanation
Er00
Unexpected fault
Problem with main circuit board hardware.
Er01
SRM not Rotate
Five attempts to start motor were unsuccessful.
Er02
RPS State Error 0
Problem with rotor position sensor (RPS) circuit. Possible
dust accumulation on RPS circuit, or defective sensor
components
Er03
RPS State Error 1
Problem with rotor position sensor (RPS) circuit. Requires
inspection by qualified personnel.
Er04 Hardware
Fault Problem
with IGBT (power circuit) section of control board,
which activates motor. Possible causes: at least one motor
phase current has reached critical value; or IGBT
components are damaged. This fault may also be caused by
inverter section or DC bus.
Er05
Unexpected Software Trap
Indicates possible bug in controller software. Cycle power to
the unit to clear.
Er13
Low Voltage
Voltage of internal DC bus on main control board is below
allowable threshold. This fault may also display when power
is turned off.
Er14
PFC Fault
Problem with power factor correction unit. Repair is advised
by qualified personnel.
Er50
Overheat
Heatsink temperature exceeds allowable threshold.
Er55
EEPROM Data Fault
Problem with main board EEPROM. Also occurs if main
board has been factory reset, powered off, then turned on
again. Power down completely, then restart unit to re-
establish factory defaults.
Er56
EEPROM Work Fault
EEPROM on main board not responding; may be missing,
broken, or tracks damaged.
dISC
Disconnected
Communication failure between HMI board and main control
board.
L.SPd
Low speed
Controller receiving signal that rotor is not turning. Probable
cause – motor windings not properly energized to turn rotor,
caused by loose connection in 6-pin motor winding cable.
11.3
Motor load display (JWL-1840DVR only)
To enter motor load display for troubleshooting purposes, proceed as follows. This can be done with lathe in
normal or educational mode.
1.
Press and hold speed knob until display flashes, then release knob.
2.
Slowly rotate knob
clockwise
for 5 detents.
3. Rotate
counterclockwise
for 3 detents.
4. Rotate
clockwise
for 2 detents.
5.
Press knob 5 times.
6.
The readout will display “Load.” Turn on lathe and readout will now display motor load instead of speed.
Load is shown as a percentage of the power capacity of the controller.
7.
Cycling power to the lathe will revert back to displaying speed.
Содержание JWL-1840DVR
Страница 30: ...30 14 2 1 JWL 1840DVR Headstock Assembly Exploded View...
Страница 34: ...34 14 4 1 JWL 1840DVR Controller Assembly Exploded View...
Страница 36: ...36 14 5 1 JWL 1840EVS DVR Bed and Stand Assembly Exploded View...
Страница 41: ...41 15 2 Schematic for JWL 1840DVR only...
Страница 42: ...42...
Страница 44: ...44 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...