Test Report No.: 17702074 003
Part I of II
Page 46 of 72
EN 1870-19:2013
Clause
Requirement
Remarks - Results
Verdict
g) environmental indicator
K
2A
and local environmental
factor
K
3A
shall be equal to or less than 4 dB;
h) difference between the background emission sound
pressure level and the workstation sound pressure
level shall be equal to or greater than 6 dB in
accordance with EN ISO 11202:2010, 6.4.1, accuracy
grade 2 (Engineering);
i) correction of the local environmental factor
K
3A
shall be
calculated in accordance with A.2 of EN ISO
11204:2010 with reference restricted to EN ISO
3746:2010 instead of the method given in Annex A of
EN ISO 11202:2010 or in accordance with EN ISO
3743-1:2010, EN ISO 3743-2:2009, EN ISO 3744:2010
or EN ISO 3745:2012 where one of these standards
has been used as the measuring method.
For noise declaration 6.3 dd) shall be met.
5.4.2.2.2
Noise emission measurement for building site saws
N/A
Emission sound power levels of building site saws shall
be measured as follows:
a) basic noise emission standard EN ISO 3744:2010 shall
be used;
b) operating conditions shall comply with A.2 b) in Annex
A of ISO 7960:1995;
c) measurement surface, number of microphone positions
and measuring distance shall comply with Annex A of
ISO 7960:1995;
d) surface sound pressure level shall be determined at
least three times. If at least two of the determined
values do not differ by more than 1 dB, further
measurements will not be necessary; otherwise the
measurements shall be continued until two values
differing by no more than 1 dB are obtained. The A-
weighted surface sound pressure level to be used for
calculating the sound power level is the arithmetic
mean of the two highest values that do not differ by
more than 1 dB.
N/A
Emission sound pressure levels at the workstation shall
be measured in accordance with EN ISO 11202:2010 with
the following modifications:
e) environmental indicator
K
2A
and local environmental
factor
K
3A
shall be equal to or less than 4 dB;
N/A
Содержание JTS-600X
Страница 2: ...8 JPW s CE declaration of conformity with latest directives and EN standards...
Страница 4: ......
Страница 5: ...10 Labels ID label motor label warning label...
Страница 19: ...Trunnion Assembly for JTS 600X...
Страница 22: ...Table and Frame Assembly for JTS 600X...
Страница 24: ...Sliding Table and Cabinet Assembly for JTS 600X...
Страница 26: ...Outriger Table and Pull out Miter Gauge Assembly for JTS 600X...
Страница 28: ...Rip Fence and Swing Arm Assembly for JTS 600X...
Страница 31: ...Mitre Gauge Assembly for JTS 600X Optional Accessory Stock Number 10000073...
Страница 32: ...Miter Gauge Assembly for JTS 600X Optional Accessory Stock Number 10000073...
Страница 47: ...Trunnion Assembly for JTS 600XL...
Страница 50: ...Table and Frame Assembly for JTS 600XL...
Страница 52: ...Sliding Table and Cabinet Assembly for JTS 600XL...
Страница 54: ...Outriger Table and Pull out Miter Gauge Assembly for JTS 600XL...
Страница 56: ...Rip Fence and Swing Arm Assembly for JTS 600XL...
Страница 59: ...Miter Gauge Assembly for JTS 600XL Optional Accessory Stock Number 10000073...
Страница 60: ...Miter Gauge Assembly for JTS 600XL Optional Accessory Stock Number 10000073...
Страница 61: ......
Страница 62: ......
Страница 70: ......
Страница 112: ...Test Report No 17702074 003 Part I of II Page 43 of 72 EN 1870 19 2013 Clause Requirement Remarks Results Verdict...
Страница 142: ......
Страница 143: ......