background image

JAT-801 Pneumatic Needle Scaler 

 

Maintenance 

Lubrication 

The needle scaler should be lubricated 

daily

 (or 

before  each  use) with  air tool  oil through  the  air 
inlet. During continual operation, it should be re-
oiled every 1 to 2 hours. This can be done with an 
in-line  oiler,  or  manually.  If  done  manually, 
proceed as follows: 

1. 

Disconnect air hose from tool. 

2. 

Place 4 or 5 drops of air tool oil into air inlet. 

NOTE: Air tool oil not provided; it is available 
at most major hardware and tool stores. SAE 
#10 oil or sewing machine oil may be used 
as a substitute. Do not use detergent oil. 

3. 

Re-connect  air.  Run  needle  scaler  at  low 
throttle  without  load  for  a  few  seconds  to 
distribute the oil throughout tool. 

4. 

When  finished  operating  needle  scaler, 
disconnect air hose. Wipe off housing with a 
dry cloth. Place 4 or 5 drops of air tool oil into 
air inlet; re-connect air and run tool for a few 
seconds to distribute the oil. Disconnect air. 

Storage  

Avoid  storing  the  needle  scaler  in  very  humid 
locations  which  promotes  rusting  of  internal 
mechanisms. Always  oil  the  tool and  disconnect 
air hose before storage. 

Air system requirements 

1. 

Use  proper  air  hose  size  (refer  to  tool 
specifications). The hose should be just long 
enough to serve the working area. Excessive 
hose length will cause pressure drop.  

2. 

Make  sure  air  compressor  supplies  clean, 
dry air at correct CFM for the tool. 

3. 

Set air pressure to 90 psi.  

 

Excess  air  pressure 

and/or unclean air will shorten the tool’s 
life and may create a hazardous situation. 

4. 

Drain water from air compressor tank daily, 
as  well  as  any  condensation  from  air  lines. 
Water in the air line may enter the tool and 
cause damage. 

5. 

Change filters on the air system on a regular 
basis. 

6. 

Air-line  pressure  may  be  increased 
accordingly to compensate for extra-long air 
hoses (usually over 25 feet). Inside diameter 
of hose should be minimum 3/8-inch. 

General Air Tool 
Information 

If  the  air  tool  is  not  performing  according  to 
specifications, the following are among the most 
common  causes.  (See  also  “Troubleshooting” 
section.) 

 

Contaminated air such as a dirty air system 
or water in the system. 

 

Using wrong size tool for the job. 

 

Poor maintenance  practices, such  as  using 
excessive air pressure or air volume. 

 

Improper or no lubrication. 

Rule of Thumb 

If it takes more than 8 seconds to tighten or loosen 
a  bolt  or  nut  with  an  air  impact  wrench  at 
maximum  setting,  the  air  wrench  is too  small  or 
the  air compressor  CFM  is  not  powerful  enough 
for  the  job.  Continued  use  in  either  capacity  will 
cause damage to the tool.  

Tool Pressure 

JET  Air Tools  operate  on  70-to-100  psi  (pounds 
per square inch) air pressure measured at the tool 
when  the  tool  is  operating.  Set  tool  to  90  psi 
unless indicated otherwise. Pressure in excess of 
100 psi will shorten the life of the tool. 

Air System Recommendations 

Equip  the  air  compressor  intake  with  a 
replaceable air filter that can be easily cleaned. 

Use  safety  shut-off  valves  so  air  flow  can  be 
stopped quickly in case of a line break. 

When using multiple hoses, air hoses should be 
larger  than  leader  hose.  Join  multiple  hoses 
directly,  rather  than  with  quick  connect  fittings 
which may cause pressure drops and tool power 
reduction. 

Содержание JAT-801

Страница 1: ...Pneumatic Needle Scaler 505801 JAT 801 Operation Parts Manual M 505801 Edition 3 11 2018 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2015 JET...

Страница 2: ...with any additional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Servi...

Страница 3: ...against the work surface 11 Do not operate air tool without its guards in place Do not modify the tool 12 Do not operate this tool while tired or under the influence of drugs alcohol or any medicatio...

Страница 4: ...clamps or vise do not hold workpiece by hand 36 Use both hands to operate needle scaler Keep hands away from needle area 37 Use only needles specifically designed for use with a needle scaler 38 Keep...

Страница 5: ...this document The instructions and warnings in this manual may not encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense As...

Страница 6: ...rottle lever Grip Inline Overall Length 16 3 8 in 415 93 mm Housing material Steel Net weight 6 08 lb 2 76 kg Shipping weight 6 50 lb 2 95 kg 1 The specified values are emission levels and are not nec...

Страница 7: ...1 If an in line oiler is not being used add 4 or 5 drops of air tool oil not included into the air inlet 7 Blow out air line to remove any dirt or moisture then connect air supply hose to tool Set air...

Страница 8: ...rdous situation 4 Drain water from air compressor tank daily as well as any condensation from air lines Water in the air line may enter the tool and cause damage 5 Change filters on the air system on...

Страница 9: ...rication Lubrication Use a light oil containing rust inhibitors such as SAE 10 Many JET air tools have integral oil reservoirs which should be kept filled when in line oilers are not used If greasing...

Страница 10: ...t lubrication Lubricate with air tool oil according to instructions in this manual Loss of power erratic action Low air pressure Verify compressor has proper CFM rating for tool Check compressor regul...

Страница 11: ...1 13 F25 11 Pin 2 8x11 2 14 F25 14 Piston 1 15 F25 15 Cylinder 1 16 F25 16 Piston sleeve 1 Index Part No Description Qty 17 F25 17 Lock ring 1 18 SB 7 16 Steel ball 7 16in 1 19 F25 19 O Ring 23 7x3 5...

Страница 12: ...epartment call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Please have the stock number and serial number of your tool available when you call so that we may serve you quickly and ac...

Отзывы: