Conceptronic CMED3PLUS Firmware Upgrade Instructions 

for firmware version: 1.54B / MP07T031408A

 

 

 

A.

 

Upgrade information

 

 

The Conceptronic CMED3PLUS is equipped with an upgradeable firmware chip. This function makes it 

possible to improve the device and to add new features. 

 

Note:  This firmware upgrade for the CMED3PLUS can only be applied to devices with firmware version 

   

1.54 (MP07T022408A) or higher. If you have a lower version you need to upgrade to version   

   

1.54 before you can apply this firmware upgrade.

 

 

Note:  The firmware upgrade procedure is at your own risk. Even though a firmware upgrade can   

   

improve the device and add new features, there’s also a possibility of an upgrade failure which 

   

makes the device unusable. Conceptronic is not responsible for this and this voids the warranty. 

 

Summary of Contents for CMED3PLUS

Page 1: ...o add new features Note This firmware upgrade for the CMED3PLUS can only be applied to devices with firmware version 1 54 MP07T022408A or higher If you have a lower version you need to upgrade to version 1 54 before you can apply this firmware upgrade Note The firmware upgrade procedure is at your own risk Even though a firmware upgrade can improve the device and add new features there s also a po...

Page 2: ... differ in hard disk connection type SATA vs IDE and the supplied remote control Since the devices are so similar it is mandatory to pick out the right product when upgrading the firmware The easiest way to identify your Media Player is through the remote control Below you see an image of both remote controls continue this firmware upgrade procedure only when you have the LEFT remote control ...

Page 3: ...the navigation buttons on the remote control The upgrade process will now start This will be visible in the upper left corner with the terms ERASE and WRITE Note The CMED3PLUS must not be turned off during the upgrade process Doing so will result in an unusable product which is not covered by the warranty 2 4 As soon as the upgrade process is completed the screen will go black Note The device is s...

Page 4: ...P file containing a folder named FW and three documentation files 1 2 Connect the USB stick or memory card to your computer 1 3 Copy the FW folder including all its content to the USB stick or memory card 1 4 Remove the USB stick or memory card from your computer with the Safely remove hardware option 1 5 Disconnect the USB stick or memory card from your computer 2 Updating the firmware 2 1 Make s...

Page 5: ...product 3 Checking the firmware version 3 1 Make sure the CMED3PLUS is connected to a TV or monitor 3 2 Select a folder by using the navigation buttons on the remote control 3 3 Press the FUNC button on the remote control select PROPERTIES and press the Enter button 3 4 Now press the Pause button II five 5 times in a row 3 5 Leave the current screen by pressing the FUNC button 3 6 When the Fast Fo...

Page 6: ...European countries solved MP07T061107A Subtitle files load automatically when a video starts to play when the subtitle file and the video file have the same file name A single folder can now contain up to 30 movies with a subtitle file Previously this was limited to 10 When playback is paused it is possible to let the screensaver start but no longer the standby mode MP07T032707A DVD navigation pro...

Page 7: ...der contents If this happens go back to folder above it and press the right navigation button on the remote control 3 Press the SUBTI button to select a subtitle 4 Press the AUDIO button to select a spoken language 5 Press the FUNC button to see information about the current file 6 Press the or button to fast forward or fast rewind 7 Press the I or I button to select a previous or next chapter 8 P...