34 | BA-40400-02-V14
Two-Channel Controller TOPAX DE
For night-time operation:
• only useful in a closed circuit.
• it can be manually switched on and off.
• the target value for the controller has to be defined.
• the percentage value can be set for reduction of recirculation
power.
• Configuring the timer is not possible.
12.1.13 Menu 5: Service
configuration
flocculation
inputs
autosetup
clock
DIN-contact
network
code
HW - Status
restart
timer
service code
logfiles
outputs
ESC
recorder
alarm action
startup
digital inputs
language
display
5
mg/l
pH
°C
26.3
7.04
0.39
Fig.33: Main menu >> menu 2 >> service
The Menu 5 “Service” covers 20 functions for the basic setting of the
TOPAX (not all functions are available):
Menu
Key
Function
0.4.4
Configuration
Repeat basic configuration
Saving and loading of a configuration
5.01
Hardware status
Hardware/software equipment
5.1
Inputs
Adjusting the input measuring ranges
5.2
Outputs
Outputs settings
53
Auto setup
not available
5.4
Reset
Reset and factory settings
5.5
Network
Configuration of RS 485 network address
(optionally available)
5.6
Logbook
Write/read the logbook
5.7
Time
Setting of date and time
5.8
Timer
not available
5.9
Password
Definition of an access code for the individual
menus
5.10
Service password Setting an access code for menu 5 "service"
5.11
DIN contact
not available
5.12
Flocculation
not available
5.13
Alarm settings
Configuration of alarm settings
5.14
Start
Setting the start delay
5.15
Recorder
0...20 mA/4...20 mA or test signal selection
5.16
Digital inputs
Digital input settings
5.17
Display
Display settings
5.18
Language
Change language and units
The various menus are described in the following pages.
To select the menus press the arrow keys
▶
,
◀
,
▲
and
▼
. Confirm the
selection with “OK”.
12.1.14 Menu 0.4.0: Configuration
The configuration of TOPAX can be changed, saved and loaded. Existing
configuration files are saved on the memory card or loaded from it.
Main menu >> menu 2 >> service >> configuration ...
... >> edit
Menu 0.4
... >> Load
Menu 0.4.20, select an existing configuration
with
the
▲
and
▼
keys and confirm with "OK".
... >> save
Menu 0.4.21, save the current configuration to
the memory card. The file name can be chosen
freely.
In this way, the configuration of the TOPAX can for instance be done for
several control circuits once and then be transferred to other, identical
TOPAX controllers via the memory card. All settings are transferred.
Furthermore, the configuration files can be saved on a PC and trans-
ferred to an identical TOPAX if required.
12.1.15 Menu 0.4.1: Configuration
next
ESC
CS120 cell (direct)
potentiostat
membrane covered cell
REDOX-Sensor
0.4.1
input disinfection
total chlorine sensor
Fig.34: Main menu >> menu 2 >> service >> configuration >> edit
IMPORTANT!
The disinfection input will be preset before delivery accord-
ing to the order and can no longer be changed.
The configuration of inputs and outputs can be modified if
necessary. Before it is saved, the newly set configuration
is indicated in red and must be saved. Use the "ESC" but-
ton to exit the menu without saving and return to the old
configuration.
When the new configuration is saved, check the terminals as well. The
new wiring diagram is displayed. The changed terminals are shown in
red writing. The terminal plan must be confirmed.
Inadmissible configurations are blocked. A text error message is shown.
For control purposes the terminal layout and assignments can be seen
in menu 5.01 “Hardware status”.
All TOPAX versions are supplied with a measuring protocol and a termi-
nal connection diagram referred to the actual configuration.