DL-FLEX-ACX • HW
Linear Strip
AC Flexible Linear Strip
PATENT NO.: US 9,671,075
www.jescolighting.com
Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 11/22/2017
Page 7 of 8
®
101663455NYM-001
B7
INSTALLING DL-FLEX-ACX-HW-CNDT
(EXTENDING CORD LENGTH WITH SPLICE BOX)
for length requirements longer than 8 feet
www.jescolighting.com
Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
+DUERU3DUN'ULYH
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
TURN OFF ELECTRICITY
DWPDLQIXVHER[RUFLUFXLWEUHDNHUER[EHIRUH
EHJLQQLQJLQVWDOODWLRQE\VZLWFKLQJFLUFXLWEUHDNHU
off or removing fuse.
0,1&6833/<&21'8&7256
HARDWARE FOR INSTALLATION
(NOT INCLUDED)
HARDWARE FOR INSTALLATION
(INCLUDED)
:,5(1876 8/5$7('63/,&(%2;
:,7+&29(5
6-7&25'
CONSULT A QUALIFIED ELECTRICIAN TO
ENSURE CORRECT BRANCH CIRCUIT
ON OFF
1
TURN OFF ELECTRICITY
AT MAIN FUSE BOX
(;7(1'('6-7&25'
QRWLQFOXGHG
02817,1*6&5(:6
63/,&(%2;&29(5
PLATE
SJT STRAIN RELIEF
3URYLGHG
$&;,1387&$%/(
8/5$7('63/,&(%2;
1/2” MC/AC
&21'8,7%86+,1*
1/2” MC/AC
)/(;,%/(&21'8,7
1/2” MC/AC
)/(;,%/(&21'8,7
µ&21'8,7
&211(&725
PREPARE SPLICE BOX TO USE
3XQFKRXWWZRNQRFNRXWVRQDVSOLFHER[DQGFRQQHFWWZRµFRQGXLWFRQQHFWRUVWRWKH
splice box, one for input connection and one for output connection.
CONNECT ACX INTO SPLICE BOX
2. Follow STEPS B2 and B3
WKHQFRQQHFWµ0&$&ÁH[LEOHFRQGXLWDVVHPEO\WRRQHRIWKH
splice box’s 3/8” conduit connectors, tighten set screw on 3/8” conduit connector to secure the
connection.
3. Reference STEP B5 to attach provided SJT strain relief on ACX input wire.
CONNECT EXTENDED SJT CORD INTO SPLICE BOX AND INTEGRAL HEATSINK PLATE:
)HHG6-7FRUGWKURXJKµÁH[LEOHFRQGXLWLQVHUWµFRQGXLWEXVKLQJRQERWKHQGVRIµ
ÁH[LEOHFRQGXLW&RQQHFWµÁH[LEOHFRQGXLWDVVHPEO\WRµFRQQHFWRUVRQVSOLFHER[DQGRQ
LQWHJUDOKHDWVLQNSODWHWLJKWHQVHWVFUHZVWRVHFXUHDOOFRQQHFWLRQV
CONNECT EXTENDED SJT CORD TO ACX INPUT CABLE
5. Connect BLACK and WHITE wires from extended SJT cord and ACX input cable, secure all
FRQQHFWLRQVZLWKZLUHQXWV8VHPRXQWLQJVFUHZVWRVHFXUHFRYHUSODWHWRVSOLFHER[
:,5(672
&211(&76833/<
WIRES
,1387
,HDWVLQN3ODWH
Surge Protection Module*
1/2” MC/AC
FLEXIBLE
&21'8,7
1/2” MC/AC
&21'8,7
%86+,1*
3/8”
&21'8,7
&211(&725
6-7&25'
STRAIN RELIEF
*NOT FOR OUTDOOR INSTALLATION
*DO NOT REMOVE SURGE PROTECTION MODULE FROM INTEGRAL HEATSINK COVERPLATE.
'RLQJVRLVLQGLUHFWYLRODWLRQWR8/UHTXLUHPHQWVDQGZLOOYRLGWKHZDUUDQW\RIWKHSURGXFW
INCORRECT BRANCH CIRCUIT CONNECTION
WILL VOID THE WARRANTY OF THE PRODUCT.
$&;,1387&$%/(