DL-FLEX-ACX • HW
Linear Strip
AC Flexible Linear Strip
PATENT NO.: US 9,671,075
www.jescolighting.com
Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 11/22/2017
Page 8 of 8
®
101663455NYM-001
C1
C2
INSTALLING DL-FLEX-HW-RADJ
www.jescolighting.com
Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
+DUERU3DUN'ULYH
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
TURN OFF ELECTRICITY
DWPDLQIXVHER[RUFLUFXLWEUHDNHUER[EHIRUH
EHJLQQLQJLQVWDOODWLRQE\VZLWFKLQJFLUFXLWEUHDNHU
off or removing fuse.
0,1&6833/<&21'8&7256
HARDWARE FOR INSTALLATION
(NOT INCLUDED)
,1-81&7,21%2;
0,1µ'(37+
8//,67('
3/4” RACEWAY
:,5(1876
CONSULT A QUALIFIED ELECTRICIAN TO
ENSURE CORRECT BRANCH CIRCUIT
ON OFF
1
TURN OFF ELECTRICITY
AT MAIN FUSE BOX
ACX
02/'('
&211(&725
%86+,1*
RACEWAY
BASE BRACKET
C2 CONNECT RACEWAY ON TO ACX INPUT CORD
6. Measure and cut metal raceway to desired length.
0RXQWPHWDOUDFHZD\·VEDVHEUDFNHWWRZDOOSHUSURGXFW·VLQVWUXFWLRQV3,DFHµEXVKLQJRQ
WKHHQGRI$&;PROGHGFRQQHFWRUFDUHIXOO\VQDSRQUDFHZD\WREDVHEUDFNHW
8. Pull through ACX input cable so that no cable is exposed past the end of raceway. Secure
provided SJT cord strain relief on ACX input cable with plier or clamping tool.
:,5(672
&211(&76833/<
WIRES
,1387
,HDWVLQN3ODWH
Surge Protection Module*
µ%86+,1*
,1387:,5(6
6833/<:,5(6
%/$&.+27
:+,7(1(875$/
*5((1RU&233(5*5281'
%/$&.+27
:+,7(1(875$/
*5((1*5281'
02817,1*
SCREWS
C1 CONNECT SURGE PROTECTION MODULE INPUT WIRES WITH SUPPLY WIRES
&RQQHFWKRWVXSSO\ZLUHEODFNWRKRWLQSXWZLUHEODFN
&RQQHFWQHXWUDOVXSSO\ZLUHZKLWHWRQHXWUDOLQSXWZLUHZKLWH
&RQQHFWVXSSO\JURXQGZLUHJUHHQRUEDUHFRSSHUWRJURXQGZLUHLQSXWZLUHJUHHQ
6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVQRWLQFOXGHG
*NOT FOR OUTDOOR INSTALLATION
*DO NOT REMOVE SURGE PROTECTION MODULE FROM INTEGRAL HEATSINK COVERPLATE.
'RLQJVRLVLQGLUHFWYLRODWLRQWR8/UHTXLUHPHQWVDQGZLOOYRLGWKHZDUUDQW\RIWKHSURGXFW
INCORRECT BRANCH CIRCUIT CONNECTION
WILL VOID THE WARRANTY OF THE PRODUCT.
$&;,1387&$%/(
&DUHIXOO\WXFNDOOFRQQHFWHGZLUHVLQVLGHWKHMXQFWLRQER[6HFXUHLQWHJUDOKHDWVLQNFRYHUSODWHWR
junction box with mounting screws (not included
PDNLQJVXUHWRQRWSLQFKDQ\ZLUHVRUZLUHQXWV
OPTION C
BLACK TO BLUE
BROWN TO WHITE