Page | 10
Setting the Functions Continued
10. Adjust Re-Hit Timer. (see screen #11 on page 7)
Get to screen #11 with [≡0.5]
showing with the 5 flashing on the display by following the instructions on pages 6&7.
The Re-Hit Timer sets a time period between the clutch shut off and a second or third
trigger-pull-clutch-shut-off sequence before an Error / Fail is registered. The Re-Hit
timer can be set between 0.0 and 9.9 seconds. To set the Re-Hit Timer, press and
release
F3
to increase the ones digit between 0 and 9. Press and release
F2
to select
the tens digit. Press and release
F3
to increase the tens digit between 0 and 9. Press
and hold
F1
for more than 2 seconds to save and exit.
Note! the Re-Hit Timer functions
only when the green Pass LED is lit upon a fastener rundown.
Additional / Common Functions
1. Reset the Count.
If it becomes necessary to terminate the assembly process before
all fasteners have been installed, the count can be reset to the starting number at any
time. To reset the count, press and hold
F3
for more than 2 seconds. The word
HIOS
will scroll across the display and the display will reset to the starting count.
2. Exiting the User Interface. (exiting also saves any changes made to the values)
The User Interface can be exited at any particular point without scrolling through the
remaining screens.
Example;
You are at the Count screen and you confirmed that the
count is set at 5. To exit (and save any changes) press and hold
F1
for more than 2
seconds. The next screen will appear briefly, the buzzer will beep twice (if enabled)
and the word
HIOS
will scroll across the display. The current count will then show and
the tool is ready to operate.
General Information
Fastener Count.
The fastener count number seen on the display always registers the
number of fasteners remaining to complete the assembly.
Counter On/OFF.
Remember that when the counter is turned off the driver operates
like a normal driver with no error proofing or counting functions.