16
PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model WF-L200V Capacity 200 Gallons (757 Liters)
Model WF-NL120V Capacity 120 Gallons (454 Liters))
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
■
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■
Model WF-L200V: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge L200V / NL120V,
part #4396702. 2004 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model WF-NL120V: Change the water filter cartridge every 6-
9 months. Use replacement cartridge L200V / NL120V, part
#4396702. 2004 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
■
The product is for cold water use only.
■
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
■
Refer to the front cover or “Accessories” section for the
Manufacturer’s name, address and telephone number.
■
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class III
*
≥
50%
≥
85%
1.9 mg/L
49,333/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.07 mg/L
640 mg/L**
0.06 mg/L
312 mg/L
>75.0%
98.7%
>75.0%
99%
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01mg/L
0.01mg/L
0.14 mg/L***
0.15 mg/L***
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.0014 mg/L
0.0069 mg/L
0.0011 mg/L
0.0042 mg/L
99.0%
95.4%
99.21%
97.08%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0059 mg/L
0.0054 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0009 mg/L
0.0007 mg/L
0.0004 mg/L
0.00043 mg/L
84.74%
87.03%
92.47%
91.93%
Benzene
0.0050 mg/L
0.0157 mg/L
0.015 ± 10%
0.002 mg/L
0.00083 mg/L
87.26%
94.71%
p-dichlorobenzene
0.075 mg/L
0.210 mg/L
0.225 ± 10%
0.0005 mg/L
0.0005 mg/L
99.76%
99.76%
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine, Taste and Odor, Particulate Class lll*;
and against ANSI/NSF Standard 53 for the reduction of Lead,
Mercury, Benzene, and p-dichlorobenzene.
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)
0.5 GPM (1.89 L/min.) @ 60 psi.
*
**
***
Class III particle size: >5 to <15 um
Test requirement is at least 10,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.