6. Open the tank valve fully by turning the valve
counterclockwise. Wait a few minutes for gas to move
through the gas line.
7. Before lighting the grill, test all connections by brushing on an
approved noncorrosive leak-detection solution. Bubbles will
show a leak.
8. If a leak is found, turn the tank valve off and do not use the
grill. Contact a qualified gas technician to make repairs.
9. Go to “Check and Adjust the Burners” section.
To Disconnect the 20 lb LP Gas Fuel Tank:
1. Check that the burner control knobs are in the “Off” position
and the grill is cool.
2. Check that the 20 lb LP gas fuel tank is in the “Off” position. If
not, turn the valve clockwise until it stops.
3. Using your hand, turn the gas pressure regulator/hose
assembly counterclockwise to disconnect to the 20 lb LP gas
fuel tank as shown.
Hand loosen only. Use of a wrench could damage the quick
coupling nut.
4. Place dust cap on cylinder valve outlet whenever the cylinder
is not in use. Only install the type of dust cap on the cylinder
valve outlet that is provided with the cylinder valve. Other
types of caps or plugs may result in leakage of propane.
5. Go to “Plug in Grill and Oven” in this section.
Plug in Grill and Oven
1. Plug into a grounded 3 prong GFI outlet.
■
To avoid electrical shock, do not immerse cord or plugs in
water or other liquid.
■
Unplug from the outlet when not in use and before
cleaning. Allow to cool before putting on or taking off
parts.
■
Do not operate any outdoor cooking gas appliance with a
damaged cord, damaged plug, or after the appliance
malfunctions or has been damaged in any manner.
Contact the manufacturer for repair.
■
Do not let the cord hang over the edge of a table or touch
hot surfaces.
■
Do not use an outdoor cooking appliance for purposes
other than intended.
■
When connecting, first connect plug to the outdoor
cooking gas appliance then plug appliance into the outlet.
■
Use only a Ground Fault Interrupter (GFI) protected circuit
with this outdoor cooking gas appliance.
■
Do not remove the ground prong or use with an adapter
of 2 prongs.
■
Use only extension cords with a 3 prong grounding plug
rated for the power of the equipment and approved for
outdoor use with a W-A marking.
2. Go to “Check and Adjust the Burners” section.
A. Gas pressure regulator/hose assembly
B. 20 lb LP gas fuel tank
A
B
A. 3-prong ground plug
B. 3-prong polarized type outdoor GFI outlet
C. Ground prong
Electrical Shock Hazard
Use only a UL listed, 14 gauge, 3 wire extension cord
approved for outdoor use, marked W-A, with a
maximum length of 50 ft.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING