Control panel
21
tof
( t i m e - o f f ) s e t t i n g
The time-off setting determines the wait interval when using the timer to control the Hydra in stand-alone
mode. The wait interval may range from 0 to 90 seconds; the default value is 2 seconds. Set as follows:
1. Under the right display, press menu as required to display
tof
.
2. Press enter to view the current value.
3. Use the up and down keys to increase or decrease the value.
4. Press enter to save the setting.
ALt
( a l t e r n a t e m e n u ) s e t t i n g
The alternate menu setting determines how heads fire in timer operation mode, i.e., when the run command
is set to
tr
. The options are shown below; the default is 0. The time-on and time-off settings determine the
fire and wait intervals.
Set as follows:
1. Under the right display, press menu as required to display
Alt
.
2. Use the up and down keys to select the desired pattern.
3. Press enter to save the setting.
Pri
( p r i m e f l u i d l i n e ) c o m m a n d
The prime fluid line command fires two heads to run fluid through the fluid line and force out air. See
“Priming the fluid line” on page 26.
Execute the command as follows.
1. Under the right display, press menu as required to display
pri
.
2. Use the up or down keys to select
y
.
3. Press enter.
StA
( h e a d s t a t u s ) r e a d o u t
The head status readout shows the operating status of each head. The possible states are shown below.
The readout is a combination of the head address and status message, with the address on the left and the
status on the right. For example, a readout of
7 R
indicates that the head at address 7 is ready. Display
head status as follows:
1. Under the right display, press menu as required to display
StA
.
2. Use the up and down keys to scroll through the head addresses.
rSt
( r e s e t ) c o m m a n d
The right display’s reset command restores the head user settings to their default values. The settings
accessible in the left display are not effected.
Select
y
(yes) to reset settings or
n
(no) to escape.
Alt Firing
pattern
0
All heads fire simultaneously
1
Sequential chase: heads fire sequentially in address order from first to last, then repeat from first
2
Bounce chase: heads fire sequentially in address order from first to last, then in reverse order back to first
3
Double sequential chase: heads fire simultaneously in address order and reverse address order
Message
Operating status
R
ready
H
heating
-
no head detected
E
error