20
Hydra user manual
HOt
( h e a d t e m p e r a t u r e ) s e t t i n g
Because fluids vaporize at different temperatures, the head temperature must be set correctly for the fluid in
use. An incorrect temperature setting causes poor performance and excessive wear and tear on the heads.
The options are
Lo
(low),
nor
(medium), and
Hi
(high); the default value is
nor
. The correct setting for
each approved fluid is shown below.
Check the setting when starting the system and whenever refilling the fluid tanks. Check or set as follows:
1. Under the right display, press menu as required to display
HOt
.
2. Press enter to view the current setting.
3. Use the up and down keys to select a different value.
4. Press enter to save the setting.
Run
( r u n ) c o m m a n d s
The run command options allow you to fire the heads in stand-alone mode, i.e., without a DMX controller.
• The
on
command fires all heads continuously at the level determined by the fog level setting.
• The
off
command stops heads from firing.
• The
tr
command initiates timer operation. In this mode, heads fire in the sequence determined by the
alternate menu setting, with the timing determined by the time-on and time-off settings, at the level
determined by the fog level setting.
To execute a run command:
1. Under the right display, press menu as required to display
run
.
2. Use the up and down keys to select a command.
3. Press enter to execute the command.
Fog
( f o g l e v e l ) s e t t i n g
The fog level setting determines the smoke density in stand-alone mode. Values range from 00 (no output)
to 20 (maximum density). The default value is 20. Set as follows:
1. Under the right display, press menu as required to display
Fog
.
2. Press enter to view the current value.
3. Use the up and down keys to increase or decrease the value.
4. Press enter to save the setting.
ton
( t i m e - o n ) s e t t i n g
The time-on setting determines the length of the firing interval, in seconds, when using the timer to control
the Hydra in stand-alone mode. The firing interval may range from 0 to 90 seconds; the default value is 2
seconds. A value of 0 will prevent the heads from firing. Set as follows:
1. Under the right display, press menu as required to display
ton
.
2. Press enter to view the current value.
3. Use the up and down keys to increase or decrease the value.
4. Press enter to save the setting.
H e a d c o n t r o l m e n u
Jem Fluid
Setting
Pro Steam Simulation Fluid
Lo
Regular DJ Fluid (DJ mix)
nor
Pro Smoke Super (ZR mix)
Hi
Pro Smoke High Density
Hi
Содержание MARTIN Hydra
Страница 1: ...Hydra user manual TM ...
Страница 35: ......
Страница 36: ...www martin com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...