Control panel
17
Located below each display are four keys with the functions described below. Approximately 25 seconds
after the last keystroke, the display exits the control menu and displays a status message.
M e n u k e y
Press the menu key to display the control menu. Press repeatedly to scroll through the menu.
E n t e r k e y
Press the enter key to display the value associated with selected menu item.
To store a new value, first change it with the up or down keys, then press the enter key until
SEt
is
displayed. If a new value is not stored, it remains active while the base is on, but is lost when the base is
turned off.
U p / D o w n k e y s
Press the up and down keys to increase or decrease setting values.
Status messages over three characters long are displayed by alternating display of two messages, for
example “Flu” and “Out”.
L e f t d i s p l a y
These messages can appear in the left display of the control panel.
R i g h t d i s p l a y
These messages can appear in the right display of the control panel.
M e n u n a v i g a t i o n
S t a t u s m e s s a g e s
Message
Occurs when...
rdy
the base is ready for non-DMX operation. Note that the heads require time to heat up and may not
be ready.
fLu Lo
the first tank is out of fluid and the base has changed over to the second tank. See “Filling the
Hydra” on page 15.
FLu OUT
both tanks are out of fluid. See “Filling the Hydra” on page 15.
CaL Err
the calibration values for the pressure sensors cannot be read. Turn off the base. If the message
still appears after turning the machine on again, contact Jem Service.
Adr 025
the base is ready for DMX operation. The number displayed is the DMX address.
OFF
a leak has been detected in the fluid line. See “Diagnosing leaks” on page 27.
Message
Occurs when...
rdy
the base is ready for non-DMX operation. Note that the heads require time to heat up and may not
be ready.
Fog 08
the heads are being fired in stand-alone mode. The number displayed is the fog level setting.
ton 04
the system is running in timed stand-alone mode and is in the firing phase of the timing cycle. The
number displayed is number of seconds remaining in the firing phase.
toF 03
the system is running in timed stand-alone mode and is in the wait phase of the timing cycle. The
number displayed is number of seconds remaining in the wait phase.
CaL Err
the calibration values for the pressure sensors cannot be read. Turn off the base. If the message