20
1 . . If .a .power .failure .occurs, .the .Infinity .memorizes .the .conditions .prior .to .the .loss .of .power . . .When .the .power . . . .
.
returns, .the .Infinity .returns .to .the .proper .point .in .the .program . .
2 . . When .power .is .returned, .the .HR:MIN .light .flashes .indicating .that .a .power .failure .has .occurred . .It . . . . . . . . . . . . . . . .
.
continues .to .flash .until .START ./ .STOP .is .pressed .
.
NOTE: The HR:MIN light flashes if the power switch is turned off and on while a
program is running and START / STOP was not pressed. It will not flash if the
power switch was turned off or a power failure occurred when the PROGRAM
READY light was on.
REPLACEMENT OF DOOR INSULATION AND SPRINGS
Infinity .M-30 .- .PN .15722 .Door .Insulation
Infinity .L-30 .- .PN .15712 .Door .Insulation
Infinity .M-30 .and .L30 .- .PN .33997 .Door .Spring .and .Hook .Assembly .Kit
1 . . Open, .locate .and .remove .the .two .screws .on .the .door .closest .to .the .door .hinges .which .hold .the .retainer .
.
strip .in .place . . .Remove .the .retainer .strip .
2 . . Remove .the .one .piece .door .insulation .by .sliding .it .toward .the .rear .of .the .furnace .and .slightly .lifting .
3 . . To .replace .the .springs, .remove .each .spring .from .the .hook .which .holds .it .in .place . . .Remove .both .the . .
.
hook .and .spring .
4 . . To .reinstall .the .new .door .insulation .or .springs .and .hooks, .reverse .the .above .procedure . .If .installing .
.
springs .and .hooks, .add .grease .to .junction .of .spring .and .hook .and .spring .and .hinge .junction .
POWER FAILURE
SERVICE
6.
When the tablet begins to melt or liquify at the edges, immediately press and hold.
Then press ENTER/REVIEW. Your Infinity is now calibrated. Three “beeps” sound and
“CAL” appears on the main display.