![JDS Uniphase PathTrak HCU200 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/jds-uniphase/pathtrak-hcu200/pathtrak-hcu200_install-and-users-manual_3580746009.webp)
Section 2: HCU200 Unpacking and Setup
2
PathTrak™ HCU200 Install User’s Guide
Rev. 000
Section 2: HCU200 Unpacking and Setup
1
Remove HCU200 from box and carefully remove all
packaging material.
2
Mount HCU200 module in rack using the four holes
provided on the front panel.
3
Connect grounding strap of chassis to Earth
Grounding termination screws on the rear panel of
the HCU200.
4
Remove the protective cover over the DC power
lugs on the rear panel of the HCU200.
a
If using an existing -48VDC power supply
double-check that power is turned off. Connect
the -48V and RTN leads from the power supply
to the appropriate power lugs on the rear panel
of the HCU200.
b
If using the JDSU-supplied optional AC power
adaptor, connect the adaptor terminals to the
appropriate HCU200 power lugs. Black wire
goes to -48VDC lug, white wire goes to RTN
lug.
5
Replace the clear plastic cover over the power lugs.
6
Connect jumpers from the RF source (commonly 8-
way splitter off of return optical receiver) to the
appropriate ports on the rear of the HCU200.
7
If using an HSM-1000 for Field View capability
please see Document 6710-30-0005 (HSM-1000
Install Guide) for details of HSM installation and
configuration.
8
Connect Ethernet feed to RJ45 connector socket on
the rear of the HCU200.
9
Apply power to the HCU200. Once power is
applied to the HCU200 the LCD will display:
Содержание PathTrak HCU200
Страница 2: ...JDSU PathTrak HCU200 Install User s Guide...
Страница 3: ......
Страница 5: ...ii PathTrak HCU200 Install User s Guide Rev 000...
Страница 7: ...iv PathTrak HCU200 Install User s Guide Rev 000...
Страница 20: ......