JDS Uniphase PathTrak HCU200 Скачать руководство пользователя страница 20

Содержание PathTrak HCU200

Страница 1: ...MONTHLY RENTALS ITAR CERTIFIED SECURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full service in house repair center WE B Sell We ww REMOTE INSPECTIO...

Страница 2: ...JDSU PathTrak HCU200 Install User s Guide...

Страница 3: ......

Страница 4: ...ted to their internal employees on a need to know basis Copyright Copyright 2010 JDSU All rights reserved System Require ments HCU200 Module 48V DC Power Supply 5 1A max current 10 100 BaseT Ethernet...

Страница 5: ...ii PathTrak HCU200 Install User s Guide Rev 000...

Страница 6: ...Guide Rev 000 iii Table of Contents Section 1 Getting to know the HCU200 1 Section 2 HCU200 Unpacking and Setup 2 Section 3 Related Information 8 Section 4 Technical Assistance 9 Section 5 Warnings 11...

Страница 7: ...iv PathTrak HCU200 Install User s Guide Rev 000...

Страница 8: ...200 PathTrak HCU200 Install User s Guide Rev 000 1 Section 1 Getting to know the HCU200 The front panel consists of The power button The 4 cursor or arrow keys The Enter or Accept button The Exit or C...

Страница 9: ...rom the power supply to the appropriate power lugs on the rear panel of the HCU200 b If using the JDSU supplied optional AC power adaptor connect the adaptor terminals to the appropriate HCU200 power...

Страница 10: ...en and Keypad Figure 2 LCD Display at Start Up 10 After approximately 20 seconds the LCD will display Figure 3 IP Address of HCU200 Figure 4 explains what each line and or symbol on the LCD is showing...

Страница 11: ...elow are the three fields which may be edited All field values may be different from what is shown Figure 5 IP address of the HCU200 Figure 6 Subnet mask of the HCU200 Figure 7 Default gateway of the...

Страница 12: ...mple process done completely from the front panel of the unit 12 To set the IP address of the HCU200 use the up or down arrow keys to scroll to the IP address field on the LCD and press the Enter butt...

Страница 13: ...Figure 11 Figure 11 IP Address in Edit Mode 1st Octet 14 Use the up or down arrow keys to set this number to the proper value range 0 thru 9 Once this number is set use the right arrow to move the cur...

Страница 14: ...field the address is set and applied When all the addresses are set verify network connectivity from the Path Trak server to the HCU200 18 The PathTrak Server AND Client must be at least version 2 6 t...

Страница 15: ...AM Product Family Series Server Client Complete DSAM Meter Func tionality Installation Guide P N 6510 30 0416 JDS Uniphase Corporation DSAM Product Family Series RPM1000 Installation Guide P N 6510 30...

Страница 16: ...Phone Number Cable TV Multimedia Products 1 800 428 4424 Ext 8350 America 1 317 788 9351 Ext 8350 World Wide catv support jdsu com Europe Africa and Mid East 49 0 7121 86 1345 Europe hotline europe j...

Страница 17: ...by doing one of the following leave a voice mail message at the Technical Assistance number in your region e mail North American Technical Assistance Center tac jdsu com or European Technical Assista...

Страница 18: ...measure ments include signal levels special equipment limited energy parts of equipment circuits powered by regulated low voltage sources and electronics WARNING If the equipment is used in a manner n...

Страница 19: ...uipment Ratings Input Connection Description 16 RF Input Ports 75 ohm dynamic voltage range 0 50 dBmV 1 Serial RS232 port 1 10 100 baseT Ethernet port 1 USB port 1 Trigger I O port 2 Earth Grounding T...

Страница 20: ......

Страница 21: ...e 1 800 638 2049 Tel 1 240 404 2999 Fax 1 240 404 2195 Latin America Tel 954 688 5660 Fax 954 846 8856 Asia Pacific Tel 852 2892 0990 Fax 852 2892 0770 EMEA Tel 49 7121 86 2222 Fax 49 7121 86 1222 www...

Страница 22: ...MONTHLY RENTALS ITAR CERTIFIED SECURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full service in house repair center WE B Sell We ww REMOTE INSPECTIO...