CleanBlast – PortaBle
aCCePtanCe CrIterIa
IS IT CLEAN
Zone Name
Diameter
Defects
Scratches
A. CORE Zone
0 – 25 μm
none
none
B. CLADDINg Zone
25 –120 μm
no limit < 2 μm
5 from 2 – 5 μm
none > 5 μm
no limit <= 3 μm
none > 3 μm
C. ADhESIvE Zone
120 – 130 μm
no limit
no limit
D. CONTACT Zone
130 – 250 μm
none => 10 μm
no limit
Zone Name
Diameter
Defects
Scratches
A. CORE Zone
0 – 65 μm
4 <= 5 μm
none > 5 μm
no limit <= 5 μm
0 > 5 μm
B. CLADDINg Zone
65 –120 μm
no limit < 2 μm
5 from 2 – 5 μm
none > 5 μm
no limit <= 5 μm
0 > 5 μm
C. ADhESIvE Zone
120 – 130 μm
no limit
no limit
D. CONTACT Zone
130 – 250 μm
none => 10 μm
no limit
The tables below list the
acceptance criteria
standardized by the
International
Electrotechnical Commission (IEC)
for single-mode and multimode connectors as
documented in
IEC 61300-3-35 Ed. 1.0.
SINgLE-mODE CONNECTORS
muLTImODE CONNECTORS