In case that a control panel output and an input are correctly configured to test the
security wired edge, the autotest sequence is automatically executed. If user wants to
enable or disable the autotest sequence a switch can be configured as “SEC.CL test”
or “SEC.OP test” in order to decide if autotest sequence is executed or not. This
configuration can be done by means of
P54
to
P5C
configuration parameters.
If autotest sequence fails control panel can try to execute again the autotest
sequence. The number of maximum number of tries can be configured by means of
the
P48
configuration parameter. This parameter can take values from 0 to 200.
Operating
After security wired edge autotest function is configured and enabled, the control
panel executes the autotest sequence every time an opening or a closing maneuver
starts. These are the autotest sequence steps:
-
In the first step the control panel removes the power supply of the security
wired edge by using the configured test output.
-
In the second step the control panel checks that the test input has no signal.
This means that the security wired edge has released its output.
-
In the third step is recovers the power supply of the security wired edge.
-
Finally in the fourth step it checks that the test input recovers the security
signal.
If any of these steps fail the autotest sequence is not OK. In case there are autotest
attempts it repeats again the sequence until the maximum number of attempts are
reached. Finally if the number of maximum number of attempts is reached autotest
error is displayed. In case of opening autotest error
Er13
is displayed and in case of
closing autotest error
Er12
is displayed.
Every autotest sequence can take at maximum 4 seconds. Therefore the autotest
maximum period depends on the number of configured attempts.
Notes
Even an autotest error happens it is possible to open/close the door by means of
Deadman mode.
Содержание GAMMA VERSUS Series
Страница 6: ...GAMMA VERSUS MANUAL 6 COD 1257066 Gamma VERSUS Manual v1 13 2 3 Sectional door 2 4 Folding door ...
Страница 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door ...
Страница 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13 ...
Страница 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13 ...
Страница 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13 ...
Страница 108: ...GAMMA VERSUS MANUAL 108 COD 1257066 Gamma VERSUS Manual v1 13 13 SAFETY INSTRUCTIONS FOR MAINTENANCE ...