GAMMA VERSUS MANUAL
40
COD. 1257066 Gamma VERSUS Manual v1.13
In the opposite hand, if the maneuver has been already programmed when a
Radioband system was connected and the RSEC/R receiver is not detected,
Er30
is
displayed to inform the user that a Radioband system was previously programmed and
now it is not detected. In this case there are two options: RSEC/R is connected again or
control panel maneuver has to be programmed again.
After setting-up the hardware, configured the parameters and programmed the
maneuver sequence, the Radioband system is ready. The programmed Radioband
transmitters will be taken into account during the normal operation as following:
-
Every time a maneuver is started the programmed Radioband transmitters are
tested (autotest process is performed). In autotest process, RSEC/R tries to
communicate via radio with the Radioband transmitter. The time needed to
perform an autotest process goes from a few milliseconds to 12 seconds at
maximum (every attempt takes about 3 seconds at maximum and the maximum
number of attempts are 4). After the 12 seconds if no Radioband transmitter
answer is received an autotest error occurs.
Er19
error for closing autotest and
Er20
error for opening autotest.
- If during normal operation Radioband security activation is detected, control
panel executes the security inversion maneuver and displays the
Wr10
or
Wr11
warning in order to inform user that activation has occurred (
Wr10
is due to a
closing security edge activation and the
Wr11
is due to opening security edge
activation).
If Radioband system is used in closing maneuver it is also possible to inhibit the
Radioband activation during a portion of the closing maneuver (the last 4cm). By using
this function, it is not necessary to avoid pressing the closing edge during the maneuver
programming sequence. Therefore it is possible to let the door completely closed with
the security edge pressed or activated. To program or configure the Radioband
inhibition zone it is necessary to use the same parameters that are used to define the
inhibition zone for wired security edges (see chapter 7.15).
If the configuration parameter
P2E
is active and the Radioband Transmitter has not yet
been programmed into the receiver RSEC/R, the control panel will operate only in
deadman mode. Likewise if you unsubscribe the Radioband transmitter to the receiver
RSEC/R, the control panel will operate in deadman mode. It will stop working in this
mode at the moment that another RadioBand transmitter is programmed again into the
receiver RSEC/R.
Notes
For more information and details regarding the Radioband system please refer to the
Radioband transmitter and RSEC/R user instructions.
Содержание GAMMA VERSUS Series
Страница 6: ...GAMMA VERSUS MANUAL 6 COD 1257066 Gamma VERSUS Manual v1 13 2 3 Sectional door 2 4 Folding door ...
Страница 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door ...
Страница 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13 ...
Страница 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13 ...
Страница 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13 ...
Страница 108: ...GAMMA VERSUS MANUAL 108 COD 1257066 Gamma VERSUS Manual v1 13 13 SAFETY INSTRUCTIONS FOR MAINTENANCE ...