© 2016 JCM American Corporation
7
Lecture Notes
November, 2016
SETTING THE LED BEZEL DEFAULT
COLOR SETTING
To set or change the LED Bezel default color setting, proceed as follows:
1. Remove power from the DBV-500 Banknote Validator Unit.
2. Set the DBV-500 DIP Switch Block #1 (Switches #1, #4, #5, #6, #7 and #8)
settings to ON.
3. Restore power to the DBV-500 Banknote Validator Unit.
4. Select the desired
Bezel LED Color
SOLID ON
by setting DIP Switch Block #2 as
indicated in Table 4 below.
5. Set DIP Switch Block #1 Switch #8 to OFF to save the Bezel LED color
configuration.
6. Remove power from the DBV-500 Banknote Validator Unit.
7. Reset all DIP Switch settings on DIP Switch Block #1 and Block #2 to the
original settings.
NOTE: Before changing settings, record the current settings of DIP Switches #1
through #8 in DIP Switch Block #2. These settings will need to be restored in order to
complete this procedure.
NOTE: To change the Bezel LED Color from a SOLID ON to a Flashing (ON/OFF)
display, set the DIP Switch Block #2 Switches (Table 4) ON for the desired LED Color,
then set Switch #8 ON to enable the Flashing function for the selected LED Color.
Table 4
LED Bezel Color Settings [Enable (Idling) State]
Bezel
LED Color
DIP Switch Block #2 Settings
1
2
3
4
5
6
7
8
GREEN
ON
CYAN
ON
BLUE
ON
MAGENTA
ON
WHITE
ON
YELLOW
ON
RED
ON
GRADIENT
(FADING)
ON
ON
ON
ON
ON
ON
ON
LED OFF
ON
ON
ON
ON
ON
ON
ON
ON