Maintenance

Important safety instructions for installation

Disconnect the power supply whenever you proceed to the installation or repair
of the control panel.

The panel must be installed while the power is disconnected.

Before installing the panel, remove all unnecessary ropes or chains and disable any equipment such as

locks that is not necessary for the automatic operation.

Before installing the panel, check that the door is in good mechanical condition, correctly balanced and

that it opens and closes correctly.

Install the manual unlocking device at a height lower than 1.8m.

Install any permanent control next to the door away from any moving part and at a minimum height of

1.5m.

For permanently connected equipment, an easily accessible power disconnection device must be incor-

porated into the wiring. It is recommended that this be of the emergency switch type.

If the control panel is supplied without emergency stop button, this will be incorporated in the installation,

connecting it to the STOP terminal.

For correct use of the security edge, this must never be activated when the door is fully closed. It is wise to

install the ends of run before activating the edge.

This equipment can only be handled by a specialist fitter, by maintenance staff or by a suitably trained

operator.

To connect the power supply and motor wiring, 2.5 mm2 section terminals must be used.

Use protective goggles when handling the equipment.

Fuses must only be handled when the appliance is disconnected from the mains.

The instructions for using this equipment must remain in the possession of the user.

European door normative EN 12453 and EN 12445 specify the following minimum protection and

door safety levels:

- for single-family dwellings, prevent the door from making contact with any object or limit the force of con-

tact (e.g. safety band), and in the case of automatic closing, it is necessary to complement this with a pres-

ence detector (e.g. photocell).

- for communal and public installations, prevent the door from making contact with any object or limit the

force of contact (e.g. safety band), and complement this with a presence detector (e.g. Photocell).

Important safety instructions for use

Do not allow children to play with the door controls.

Keep the remote controls out of the reach of children.

Watch the door movement and keep people away until the door is fully open or closed.

Precaution when operating the manual unlocking device, as the door may suddenly fall due to the bad

condition of the springs or door unbalance. Details on how to use the manual unlocking device must be

provided by the manufacturer or the device installer.

Examine the installation frequently, especially the cables, springs and supports, to detect signs of wear,

damage or unbalance. Do not use the door if repair work or adjustments are required, as this may cause

damage.

Use of the equipment

Designed for automation of garage doors, in accordance with the general description. Not guaranteed for other uses. The man-

ufacturer reserves the right to alter equipment specifications without prior notification.

jcm

technologies

2

Содержание EASY-ROLL

Страница 1: ...User s Manual EASY ROLL...

Страница 2: ...be handled when the appliance is disconnected from the mains The instructions for using this equipment must remain in the possession of the user European door normative EN 12453 and EN 12445 specify t...

Страница 3: ...erature 20 C to 85 C Airtightness IP54 with IP65 packing seal Box dimensions 140 x 220 x 55 mm RadioBand characteristics Parameter Value Frequency 868 90MHz Memory 6 RADIOBAND T Range guaranteed 10 me...

Страница 4: ...pen and close The first press opens the second press stops until the limit switch and the third closes Stop STOP Contact normally closed This detains the operation on standby for a new order Where not...

Страница 5: ...hen pressed for the second time and it closes when pressed for the third time if the end of the opening time is complete If not it continues to open 3 Open close dead man operating Turn options 1 and...

Страница 6: ...for the security open contact No auto test carried out 5 OPEN STOP OPEN The panel always opens until the end of the opening time Alternative operation open stop close stop 6 AUTO CLOSE Automatic clos...

Страница 7: ...ming press the PANEL PROG button again and keep it pressed down until the red pilot light flashes and the equipment emits a short acoustic signal The equipment will now have entered open close program...

Страница 8: ...the equipment will exit programming mode issuing two 1 sec acoustic signals RADIOBAND RC RCS OPERATIONS Use the PROG RB programming button to programme the safety edges Follow the RADIOBAND system ins...

Отзывы: