background image

1- Automatic operation

Using buttons, radio transmitters or radio buttons

Turn option 6 (AUTOCLOSE) on the option switch to ON.

Connect a NO start/stop button on the terminals marked START. This button carries out two functions: start and stop.

Depending on the version, it is possible to use the terminals indicated as OPEN, CLOSE and STOP to make the movement.

If option 5 on the option switch is turned to ON, the motor starts when the button is pressed for the first time. It stops when

pressed for the second time and it closes when pressed for the third time if the end of the opening time is complete. If not, it

continues to open.

2- Semi-automatic operation (default option)

Using buttons, radio transmitters or radio buttons

Turn option 6 (AUTOCLOSE) on the option switch to OFF.

Connect a NO start/stop button on the terminals marked START. This button carries out two functions: start and stop.

Depending on the version, it is possible to use the terminals indicated as OPEN, CLOSE and STOP to make the movement.

If option 5 on the option switch is turned to ON, the motor starts when the button is pressed for the first time. It stops when

pressed for the second time and it closes when pressed for the third time if the end of the opening time is complete. If not, it

continues to open.

3- Open/close dead man operating

Turn options 1 and 2 on the option switch to ON.

Using pushbuttons

Connect two pushbuttons. One on the OPEN terminal that will operate as a dead man button in opening, and the other on the

CLOSE terminal that will operate as a dead man button in closing.

By radio

Radio dead-man operations are only possible using the radio button or the radio key switch, previously programmed on the

equipment. It is not possible with transmitters.

4- Semi-automatic operating in opening and dead man operating in closing

Turn option 2 on the option switch to ON.

Using pushbuttons

Connect two pushbuttons. One on the OPEN or START terminal that will operate as a start button in opening, and the other on

the CLOSE terminal that will operate as a dead man button in closing.

By radio

Radio dead-man operations are only possible using the radio button or the radio key switch, previously programmed on the

equipment. It is not possible with transmitters.

In automatic or semi-automatic mode, dead-man operations can be forced using the OPEN,
CLOSE and/or radio buttons. During this operating mode, the panel will take no enabled secur-
ities into account.

jcm

technologies

5

Содержание EASY-ROLL

Страница 1: ...User s Manual EASY ROLL...

Страница 2: ...be handled when the appliance is disconnected from the mains The instructions for using this equipment must remain in the possession of the user European door normative EN 12453 and EN 12445 specify t...

Страница 3: ...erature 20 C to 85 C Airtightness IP54 with IP65 packing seal Box dimensions 140 x 220 x 55 mm RadioBand characteristics Parameter Value Frequency 868 90MHz Memory 6 RADIOBAND T Range guaranteed 10 me...

Страница 4: ...pen and close The first press opens the second press stops until the limit switch and the third closes Stop STOP Contact normally closed This detains the operation on standby for a new order Where not...

Страница 5: ...hen pressed for the second time and it closes when pressed for the third time if the end of the opening time is complete If not it continues to open 3 Open close dead man operating Turn options 1 and...

Страница 6: ...for the security open contact No auto test carried out 5 OPEN STOP OPEN The panel always opens until the end of the opening time Alternative operation open stop close stop 6 AUTO CLOSE Automatic clos...

Страница 7: ...ming press the PANEL PROG button again and keep it pressed down until the red pilot light flashes and the equipment emits a short acoustic signal The equipment will now have entered open close program...

Страница 8: ...the equipment will exit programming mode issuing two 1 sec acoustic signals RADIOBAND RC RCS OPERATIONS Use the PROG RB programming button to programme the safety edges Follow the RADIOBAND system ins...