GENERAL DESCRIPTION

Control panel with built-in receiver and Radioband system for axis centre motors and automatisms for roller doors and shut-

ters. For three types of operations: automatic operations, semi-automatic operations and “dead man” operations (with radio

buttons). Allows for 15 transmitters to be memorised.

It is fitted with one inlet for the start/stop button and one for the two security edges and an output for photocell supply and one

for autotesting.

Programming the independent opening and closing times.

INSTALLATION AND CONNECTIONS

Fit the rear of the box to the wall using the rawlplugs and screws supplied. Pass the cables through the bottom of the equip-

ment. Connect the power supply cables to the terminals on the printed circuit, following the indications engraved on the board.

Fit the front of the equipment to the rear using the screws supplied.

If the door does not open when the button is first pushed, invert the motor cables.

OPERATION

Start (START)

Contact normally open to open and close. The first press opens, the second
press stops (until the limit switch) and the third closes.

Stop (STOP)

Contact normally closed. This detains the operation on standby for a new
order. Where not used, turn option 3 (STOP) on the input switch to ON.

OPEN

Contact normally open to open. If it is pressed while the door is closing, it will
stop and open.

CLOSE

Contact normally open to close. If it is pressed while the door is closing, it will
not be triggered.

Security contact (SEC.CL. /
SEC.OP.)

Contact normally closed, photocell or magnetic detector type. This acts on
opening and closing, causing stoppage and inversion. Where not used, turn
option 1 or 2 on the input switch to ON.

Auto-test outlet (TEST SEC.)

24 Vac outlet for auto-test of security parts.

24 Vac outlet

To power any equipment at a voltage of 24 Vac with a maximum con-
sumption of 100 mA.

Auxiliary contact outlet

Voltage-free contact to activate garage light, for example (maximum 10 A).

Safety edge

On opening it causes stoppage and inversion of 2 s and on closure causes
stoppage and complete movement inversion.

Power: When the panel is switched on, the green pilot light indicates the correct power
supply to the equipment.

jcm

technologies

4

Содержание EASY-ROLL

Страница 1: ...User s Manual EASY ROLL...

Страница 2: ...be handled when the appliance is disconnected from the mains The instructions for using this equipment must remain in the possession of the user European door normative EN 12453 and EN 12445 specify t...

Страница 3: ...erature 20 C to 85 C Airtightness IP54 with IP65 packing seal Box dimensions 140 x 220 x 55 mm RadioBand characteristics Parameter Value Frequency 868 90MHz Memory 6 RADIOBAND T Range guaranteed 10 me...

Страница 4: ...pen and close The first press opens the second press stops until the limit switch and the third closes Stop STOP Contact normally closed This detains the operation on standby for a new order Where not...

Страница 5: ...hen pressed for the second time and it closes when pressed for the third time if the end of the opening time is complete If not it continues to open 3 Open close dead man operating Turn options 1 and...

Страница 6: ...for the security open contact No auto test carried out 5 OPEN STOP OPEN The panel always opens until the end of the opening time Alternative operation open stop close stop 6 AUTO CLOSE Automatic clos...

Страница 7: ...ming press the PANEL PROG button again and keep it pressed down until the red pilot light flashes and the equipment emits a short acoustic signal The equipment will now have entered open close program...

Страница 8: ...the equipment will exit programming mode issuing two 1 sec acoustic signals RADIOBAND RC RCS OPERATIONS Use the PROG RB programming button to programme the safety edges Follow the RADIOBAND system ins...