CAPTIVE SYSTEM
jcm
technologies
26
7.
Checking and maintenance
7.1.
Does the equipment work properly?
Once the safety edge is wired and programmed into the receiver, R1 and / or R2 (according to programming mode) are
not illuminated (OFF). Also IN1 and IN2 LEDS at the transmitter are at OFF.
If the safety edge has been programmed in R1 and R1 LED is at ON, check that the safety edge is not pushed/detecting
(IN1 LED at ON on the transmitter) or it is not properly configured (IN1 LED flashing on the transmitter). If IN1 LED is
at OFF and R1 LED is at ON, check status of other transmitters memorized.
The IN1 and IN2 LEDs of the transmitter will pass to battery saving mode (off) 5 minutes after pressing PROG on the
transmitter. They can re-awaken again pressing the PROG button on the transmitter.
If there is no safety edge programmed in R1 and / or R2, it will be in safety mode (opened and LED at ON)
If R1 / R2 LEDs are OFF, but the door does not move, check that the wiring to the control panel is made correctly as
safety contact or resistive safety edge input.
Check also if LED indicator on MAGIN detector changes to red color in the desired inhibition zone, and the INH LED on
the receiver is switched ON.
7.2.
Check the correct operation
Press the safety edge to assure that the appropriate relay on the receiver is activated.
If not, see the Troubleshooting table, to check what is happening and how to solve it.