Technical characteristics
Panel supply
230Vac
Power
3/4CV
Receiver
868,35MHz integrated 15 codes (only BASIC-PLU
and BASIC+MN versions) and pluggable receiver
card (433.92 / 868.35 MHz)
Security device output
24Vac /0,3A
Garage light contact
230Vac (máx 100W)
Operating temperature
-20ºC to +85ºC
Watertightness
IP54
Equipment category
Class II
Sizes
150x110x40mm / 130x95x40mm (BASIC+MN)
Box size
225x195x85 mm
Installation
Any handling of the panel for installation must be carried out with the power supply disconnected.
Fitting the casing (only version with casing)
Parts: front casing and container box.
Unscrew the securing points. Insert the cables through the lower holes.
Important considerations for start-up
If the door does not open when the button is first pushed, invert the motor cables.
Where inversions are made, the panel adds time to ensure the door closes.
Any optional cards must be connected to the panel with the power supply disconnected.