ATEST signal polarity (depends on the control panel)
SW4
↑
Negative
ATEST negative: ATEST signal is a fixed 12 or 24V signal
that the control panel sets to 0V to make the system check.
↓
Positive
ATEST positive: ATEST signal is disconnected and when
the control panel makes a testing gives a 12 or 24V signal.
In case of operating without ATEST signal, it is necessary to work in ATEST positive
way. In order to comply with the EN ISO 13849-1: 2015 safety standard, you must
connect this signal to test the system.
ON/WORK mode
The operating mode is selected by the SW2 of the receiver. This selector is neces-
sary when working with optical safety edges. All transmitters in the receiver work in
the same way. It will be necessary to reset the receiver when changing the oper-
ating mode with transmitters already memorized.
With standard optical safety edges, WORK mode must be used due to high con-
sumption of the optical elements.
With OSE-S7502B and OSE-S7502 "always on" optical safety edges, both modes
are allowed. In ON mode, the system becomes universal for any control panel. In
WORK mode the battery life is maximized thanks to the shutdown of the optical ele-
ments.
jcm
technologies
11
Содержание RADIOBAND3G
Страница 1: ...RB3 R868 RB3 T868 RB3 T868W RB3 R868W User Manual...
Страница 5: ...Receiver RB3 R868 jcmtechnologies 5...
Страница 6: ...Transmitter RB3 T868 jcmtechnologies 6...
Страница 7: ...Assembly and installation Installation of the equipment jcmtechnologies 7...
Страница 8: ...jcmtechnologies 8...
Страница 14: ...jcmtechnologies 14...
Страница 22: ...Troubleshooting jcmtechnologies 22...
Страница 26: ...Notes jcmtechnologies 26...
Страница 27: ...Notes jcmtechnologies 27...