Section 2
UBA Pro RT/RQ™ Series Banknote Recycler
Installation
© 2020, JAPAN CASH MACHINE CO., LTD.
2 - 1 8
Table 2-12
RT/RQ Sensors and Cleaning Methods
Sym.
Sensors
Cleaning Method
A
Note Position Sensor A (RT Transport)
Wipe clean using a dry, lint free cloth, cotton
swab.
B
Note Position Sensor B (RT Transport)
C
Note Position Sensor C (RT Transport)
D
Note Position Sensor D (RQ Transport)
E
Note Position Sensor E (RQ Transport)
F
Note Position Sensor F (RQ Transport)
G
1
Drum 1 Tape Full Empty Sensor 1
(RT/RQ Transport)
Clean using non-flammable Compressed Air.
2
Drum 2 Tape Full Empty Sensor 2
(RT/RQ Transport)
H
Exit Prism
Wipe clean using a dry, lint free cloth, cotton
swab.
I
1 Note Position Sensor 1 (RT Transport)
Wipe clean using a dry, lint free cloth, cotton
swab.
2 Note Position Sensor 2 (RT Transport)
3 Note Position Sensor 3 (RT Transport)
*This sensor is not visible.
Clean using non-flammable Compressed Air.
4 Note Position Sensor 4 (RQ Transport)
Wipe clean using a dry, lint free cloth, cotton
swab.
5 Note Position Sensor 5 (RQ Transport)
6 Note Position Sensor 6 (RQ Transport)
NOTE: Wipe and clean all of the
Green
colored Rollers and Belts shown in Figure 2-30 using a
slightly damp, lint-free, Micro-fiber cloth. Do not allow liquids or fluids to drip into the Unit, to
minimize the risk of damage or improper performance.