© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 1 5
Calibration and Testing
UBA Pro RT/RQ™ Series Banknote Recycler
Section 6
Solenoid Test (RQ Transport)
To perform the Recycler’s Solenoid Test on the RQ
Transport side, proceed as follows:
1. Ensure that the Recycler and Cash Box is prop-
erly installed.
2. Launch the Performance Test Program (see
page 6-7).
3. Select “
QUAD_SOLENOID_TEST
” (Figure 6-65
a
).
4. Click the “
Start
”
Screen Button (Figure 6-
b
) to begin the Test.
5. Confirm the “
ON/OFF
” indication in the “
RC-
Solenoid (RC-Quad)
a
) is
switched as Solenoid moves.
6. Click the “
Stop
”
b
) to end the test.
Drum 1 Motor Speed Test (RQ Transport)
To perform the Drum 1 Motor Speed Test on the
RQ Transport side, proceed as follows:
1. Ensure that the Recycler and Cash Box is prop-
erly installed.
2. Launch the Performance Test Program (see
3. Select “
QUAD_DRUM_MOTOR_TEST1
” (Fig-
a
).
4. Click the “
Start
”
Screen Button (Figure 6-
b
) to begin the Test.
5. The measured speed will appear in the “
RC-Drum
Motor 1 (RC-Quad)
a
) on the
Screen.
6. Confirm that the motor speed is in the acceptable
range:
700mm/sec to 950mm/sec (Forward/Reverse)
7. Click the “
Stop
”
Screen Button (Figure 6-
b
) to end the test.
Figure 6-65
Solenoid Test (RQ Transport) 1
Figure 6-65
Solenoid Test (RQ Transport) 1
a
b
Scroll
Figure 6-66
Solenoid Test (RQ Transport) 2
Figure 6-66
Solenoid Test (RQ Transport) 2
a
Scroll
b
Figure 6-67
Figure 6-67
Drum 1 Motor Speed Test
(RQ Transport) 1
a
Scroll
Figure 6-68
Figure 6-68
Drum 1 Motor Speed Test
(RQ Transport) 2
a
Scroll
b