© 2020, JAPAN CASH MACHINE CO., LTD.
1 - 3
General Information
UBA Pro RT/RQ™ Series Banknote Recycler
Section 1
3.
(Type 3)
Do not install the unit in a dusty
environment. Dust may damage the unit or
degrade its performance.
User Cautions
Careful measures are taken in the design of this
product to ensure its quality; however, the follow-
ing cautions should be read and understood by all
users in order to confirm safe operation.
Installation Cautions
The Installation Cautions are defined as follows:
1. Do not allow the Unit to endure or operate at a
high temperature, in high humidity and/or in a
dusty environment. (Refer to “Environmental
2. Do not install the Unit into an area where exces-
sive vibration or shock are present.
3. The Unit is not designed for outside installation.
Be sure that the Host Machine contains enough
protection to avoid wet or dusty conditions when
installing in either an indoor or open-air space.
4. Avoid exposing the Unit to direct Sunlight and/or
Incandescent Lamp illumination. (Refer to
“Environmental Specifications” on page 1-8.)
5. Ensure that the Host Machine is designed for
daily operational access for maintenance and/or
clearing a Banknote jam. (Refer to “Unit Dimen-
6. When installing the equipment, connect the
Frame Housing to the Frame Ground of the Host
Machine.
7. If an unused Interface Harness exists, cut the
Harness off short to avoid attracting static elec-
tricity or a short circuit possibility that may cause
damage to the Unit.
8. Because this equipment is a component product,
close the Host Machine’s door before using it.
9. Do not operate the
RT/RQ Unit without the Cash
Box and/or the Recycler or while the Cash Box
and/or the Recycler’s door is open. Do not use
the Unit where it may be exposed to airborne
evaporated or sporadic chemicals and/or oil.
10. Do not use the Unit where it may be exposed to
airborne evaporated or sporadic chemicals and/or
oil.
11. Ensure that the Host Machine is designed consid-
ering the risk of electronic components that can
cause induced noise. The noise generated by the
components on the Host Machine may affect and
degrade the Validation performance.
Mounting, Dismounting & Transportation
Methods for Mounting, Dismounting, and Trans-
porting the Unit are as follows:
1. Be sure to remove the Power from the RT/RQ
Unit before attaching or unplugging Connector
Plugs to avoid the risk of damage to the Unit.
2. Be sure to carry the Unit by both hands when
transporting it. Holding the Unit by one hand
may cause personal injury if the Unit accidentally
becomes disassembled and falls away from the
Frame housing.
3. Be careful not to use excessive outside pressure
on the Recycler, or subject it to excessive vibra-
tion during transportation.
4. Check that the UBA Pro Unit does not drop off
the Unit Frame while pulling the Recycler for-
ward from the Frame.
Operation Cautions
The Operation Cautions are defined as follows:
1. When closing the UBA Pro Unit, ensure it firmly
clicks into place.
2. When installing the Recycler, ensure it firmly
clicks into place.
3. Do not remove the Recycler and/or the Cash Box
during operation.
4. Do not throw or apply strong external pressure on
the Recycler.
5. Be sure to follow the specified measures when
removing or re-seating any removal unit of the
RT/RQ Unit. Improper handling may cause per-
sonal injury and/or damage to the equipment.
6. The Recycler is not protected by a key. Caution is
advised for cash handling.
Preventive Maintenance
The Preventive Maintenance requirements are
defined as follows:
1. Be sure to remove the Power from the RT/RQ
Unit before cleaning or a cleaning or mainte-
nance procedure, except for the Recycler and the
Cash Box. Cleaning or performing maintenance
while the Power is turned on may cause personal
injury if the Unit mechanisms accidentally move.
2. To keep the RT/RQ Unit’s performance optimal,
clean and maintain the RT/RQ Unit regularly
based on the Unit condition and/or maintenance
schedule. (Refer to “Cleaning Procedure” on
3. Do not redesign or disassemble the Recycler.
Unauthorized use by inadequately-trained
personnel, or use outside the original manufac-
turer’s intent for operation voids the warranty.
4. Perform cleaning and maintenance regularly
when using the equipment in an smoky environ-
ment such as where excessive Automobile
exhaust emission or Cigarette Smoke may exist.
WARNING: Make sure Interface Harness
connections to the Host Machine are
shorter than 9.84 Feet (3 Meters) in
length. Cut off all unused portions of
the Interface Harness wiring to avoid
static electrical effects or short circuit
possibilities that could cause damage
to the Unit.
WARNING: Do not inject water or liquid
agents of any kind into the Unit, as this
may cause extreme damage to the Unit.