MANUAL Color Mode: 
Set rotation, strobe and the 3 basic colors (red-green-blue) manually to compose precisely what you 
need:  

 

  Press the [MENU] button until 

[CoLo]

 is shown on the display 

  Press [ENTER] to access the function settings 

  [red] will appear on the display 

  Press [ENTER] if you want to modify the settings of the red color  

  Use the UP and DOWN buttons to modify the intensity of the color  

  Press [ENTER] to save your setting. 

  You can now use DOWN and UP to go to the next color. 

 

… 

  Once the intensity settings for the red, green and blue color are done:  

  Use UP button to go to the next option: 

[Noto]

 will appear on the display.  

  Press [ENTER] if you want to modify the settings of the motor. 

  Use DOWN and UP buttons to change the rotation speed or blade position: 

o

 

000 to 127 = no rotation / blade position 

o

 

128 to 255 = fast rotation to slow rotation 

  Press [ENTER] to confirm  

  Use UP button to go to the next option: 

[Stro]

 will appear on the display.  

  Press [ENTER] if you want to modify the strobe setting. 

  Use DOWN and UP buttons to change the strobe speed.  

o

 

000 = no strobe 

o

 

001 to 255 = fast strobe to slow strobe effect 

  Press [ENTER] to confirm 

 
MASTER/SLAVE Mode  
Used when you want to have synchronized effects with several units. (when no controller is used and 
the first unit 

is running it’s automatic programs or is set in a fixed color)

   

 

  Press the [MENU] button until [

MorS

] is shown on the display.  

  Press [ENTER] to access the function settings 

  Use DOWN and UP buttons to change the working mode: 

o

 

[mASt]  should  be  chosen  for  the  first  unit  in  the  chain.  This  unit  will  control  the  other 
connected slave units 

o

 

[SALu] should be chosen for all the unit in the chain that should follow the instructions of the 
“master” unit. 

  Press [ENTER] to confirm 

 

SOUND SENSITIVITY 
Used when to set the sound sensitivity of the integrated microphone

 

 

  Press the [MENU] button until [

SEnS

] is shown on the display.  

  Press [ENTER] to access the function settings 

  Use DOWN and UP buttons to change the sensitivity from 1 (low) to 100 (high) 

o

 

[mASt]  should  be  chosen  for  the  first  unit  in  the  chain.  This  unit  will  control  the  other 
connected slave units 

o

 

[SALu] should be chosen for all the unit in the chain that should follow the instructions of the 
“master” unit. 

  Press [ENTER] to confirm 

 

REVERSE DISPLAY 
Used to invert the display information when the unit is placed upside-down

 

 

  Press the [MENU] button until [

dISP

] is shown on the display.  

  Press [ENTER] to access the function settings 

  Use DOWN and UP buttons to change the setting  

o

 

[YES] invert display (upside-down) 

o

 

[no] don

’t invert display. 

  Press [ENTER] to confirm 

 

Содержание LED FAN RGB

Страница 1: ......

Страница 2: ......

Страница 3: ...nsult your dealer first Important This device left our factory in perfect condition and well packaged It is absolutely necessary for the user to strictly follow the safety instructions and warnings in...

Страница 4: ...tions for electrical and mechanical safety in your country Check that the available voltage is not higher than the one stated on the unit The power cord should always be in perfect condition Switch th...

Страница 5: ...ntion to the maximum load while adding projectors Special Multi cables PowerCON DMX XLR cables are available on the market 11 MAINS FUSE protects the unit in case of electrical problems always use the...

Страница 6: ...ing immediately in the last selected mode Refer to chapter HOW TO SETUP to learn how to switch between the different working modes Electrical installation for two or more units in master slave Connect...

Страница 7: ...e display 4Ch 8Ch or 11Ch Use the DOWN and UP buttons if you would like to change the working mode Press the ENTER button to confirm AUTOMATIC Modes Used to set an automatic Chase Mode at a constant s...

Страница 8: ...ou want to have synchronized effects with several units when no controller is used and the first unit is running it s automatic programs or is set in a fixed color Press the MENU button until MorS is...

Страница 9: ...it OPERATING INSTRUCTIONS A Standalone 1unit Just connect the unit to the mains Select one of the automatic sound or static modes Refer to chapter HOW TO SETUP to learn how to make the settings B Two...

Страница 10: ...ed 1 0 100 LEDs SECTION 1 6 000 255 Green 1 0 100 7 000 255 Blue 1 0 100 8 000 255 Red 2 0 100 LEDs SECTION 2 9 000 255 Green 2 0 100 10 000 255 Blue 2 0 100 11 000 127 Position MOTOR 128 191 Clockwis...

Страница 11: ...o interference suppressed This product meets the requirements of the current European and national guidelines Conformity has been established and the relevant statements and documents have been deposi...

Страница 12: ......

Отзывы: