Section 8: Plumbing System
105
the water from the water heater tank whenever the RV is not being used. Avoid any extended
time of non-use with water in the tank.
To prevent a water leak when replacing the anode rod, a pipe thread sealant approved for
potable water (such as Teflon Tape) must be applied to the threads of the anode rod. Proper
application of a thread sealant will not interfere with the anode.
High altitude deration
Operation of the water heater at high altitudes may require derating. If the water heater is
not properly derated, lack of sufficient oxygen for combustion may produce improper burner
operation. Pilot outage caused by burner lift-off or sooting from a yellow burner may occur,
indicating the possibility of carbon monoxide. You may also notice a lack of efficiency in
heating the water because of incomplete combustion of the burner at these higher altitudes.
Consult with the local propane company, your dealer or the water heater manufacturer for
proper derating of the water heater. Change out of the orifice (derating) should be done by
the dealer or a qualified service agency.
Pressure & temperature relief valve
The temperature and pressure relief valve is designed to open if the temperature of the water
within the heater reaches 120° F, or if the water pressure in the heater reaches 150 pounds.
When this pressure is reached, the pressure relief valve will open and water will drip from
the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150 pounds,
and the valve closes. This condition is normal and does not indicate a defective relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater. To replenish this air pocket:
1.
Turn off the water heater.
2.
Turn off the cold water supply line.
3.
Open a faucet in the recreation vehicle.
4.
Pull out the handle of the pressure relief (P&T) valve and allow water to flow from the
valve until it stops.
5.
Release the handle on the P&T valve - it should snap closed.
Close the faucet and turn on the cold water supply. As the tank fills, the air pocket will
develop. Repeat this procedure as often as needed to reduce the frequency of the weeping
P&T valve.
Do not place a valve between the pressure and temperature (P&T) valve and
the tank. Do not remove or plug the relief valve under any circumstances.
NOTE:
It is important that once the RV has returned to lower eleva
-
tion (below 4500 feet) any high altitude deration or other adjustments
be reversed for proper operation of the water heater.
Table of Contents
Maintenance Record
Содержание JAY SPORT 2018
Страница 1: ...Owner sManual PRINTED ON RECYCLED PAPER 0181064 2018 2018 CAMPINGTRAILERS...
Страница 2: ......
Страница 4: ......
Страница 8: ...H Table of Contents Maintenance Record...
Страница 10: ...Section 1 Warranty Service 2 Table of Contents Maintenance Record...
Страница 78: ...Section 5 Slideout Systems 70 Notes Table of Contents Maintenance Record...
Страница 92: ...Section 6 Electrical System 84 Notes Table of Contents Maintenance Record...
Страница 102: ...Section 7 Fuel Propane System 94 Notes Table of Contents Maintenance Record...
Страница 130: ...Section 12 Interior 122 Notes Table of Contents Maintenance Record...
Страница 136: ...Section 13 Exterior 128 Notes Table of Contents Maintenance Record...
Страница 140: ...Section 14 Additional Information 132 Notes Table of Contents Maintenance Record...
Страница 144: ...Section 15 Additional Information 136 Notes Table of Contents Maintenance Record...