background image

CFL/LED

 

RATING

 

Incandescent

 

RATING

 

Number

 

of

 

Dimmers

 

Heat

 

Sink

 

150W

 

600W

 

1

 

Switch

 

in

 

Single

 

Gang

 

Box

 

Full

 

 

No

 

tabs

 

removed

 

1

25

W

 

5

00W

 

2

 

Switches

 

in

 

Double

 

Gang

 

Box

 

One

 

tab

 

removed

 

(Inner)

 

1

0

0W

 

4

00W

 

3

 

Switches

 

in

 

Triple

 

Gang

 

Box

 

Both

 

tabs

 

removed

 

Observe

 

Important

 

Wiring

 

Information

 

Important:

 

This

 

switch

 

is

 

rated

 

for

 

and

 

intended

 

to

 

only

 

be

 

used

 

with

 

copper

 

wire.

 

The

 

home’s

 

electrical

 

wires

 

may

 

be

 

attached

 

to

 

the

 

screw

 

terminals

 

or

 

inserted

 

into

 

the

 

holes

 

in

 

the

 

back

 

of

 

the

 

switch

 

enclosure

 

and

 

clamped

 

in

 

place

 

by

 

tightening

 

the

 

screw

 

terminals.

 

Always

 

follow

 

the

 

recommended

 

wire

 

strip

 

lengths

 

when

 

making

 

wiring

 

connections.

 

Wire

 

gauge

 

requirements

 

• Use

 

14

 

AWG

 

or

 

larger

 

wires

 

suitable

 

for

 

at

 

least

 

80°

 

C

 

for

 

supply

 

(HOT),

 

Load,

 

Neutral,

 

Ground

 

and

Traveler

 

connections.

 

Wire

 

strip

 

length:

 

• For

 

attachment

 

to

 

screw

 

terminals:

 

Strip

 

insulation

 

1

 

in

 

(25mm)

• For

 

attachment

 

using

 

the

 

enclosure’s

 

holes:

 

Strip

 

insulation

 

5/8”

 

(16mm)

UL

 

specifies

 

that

 

the

 

tightening

 

torque

 

for

 

the

 

screws

 

is

 

14

 

Kgf

cm

 

(12

 

lbf

in).

 

SINGLE

 

SWITCH

 

WIRING

  

1. Shut

 

off

 

power

 

to

 

the

 

circuit

 

at

 

fuse

 

box

 

or

 

circuit

 

breaker.

2. Remove

 

wall

 

plate.

!

 

Warning:

 

Verify

 

power

 

is

 

OFF

 

to

 

switch

 

box

 

before

 

continuing.

 

3. Remove

 

the

 

switch

 

mounting

 

screws.

4. Carefully

 

remove

 

the

 

switch

 

from

 

the

 

switch

 

box.

 

DO

 

NOT

 

disconnect

 

the

 

wires.

5. There

 

are

 

five

 

screw

 

terminals

 

on

 

the

 

switch;

 

these

 

are

 

marked

LINE

 

(Hot)

Neutral

LOAD

GROUND

TRAVELER

The

 

Traveler

 

terminal

 

is

 

only

 

used

 

for

 

3

way

 

or

 

4

way

 

wiring

 

and

 

should

 

remain

 

insulated

 

if

 

the

 

switch

 

is

 

being

 

installed

 

in

 

a

 

2

way

 

system

 

(one

 

switch

 

&

 

one

 

load).

 

Match

 

these

 

screw

 

terminals

 

to

 

the

 

wires

 

connected

 

to

 

the

 

existing

 

switch.

  

6. Disconnect

 

the

 

wires

 

from

 

the

 

existing

 

switch.

7. Connect

 

the

 

green

 

or

 

bare

 

copper

 

ground

 

wire

 

to

 

the

 

GROUND

 

terminal.

8. Connect

 

the

 

black

 

wire

 

that

 

goes

 

to

 

the

 

light

 

to

 

the

 

terminal

 

marked

 

LOAD.

9. Connect

 

the

 

black

 

wire

 

that

 

comes

 

from

 

the

 

electrical

 

service

 

panel

 

(Hot)

 

to

 

the

 

terminal

 

marked

LINE.

 

Содержание ZigBee ZB3001 (45857)

Страница 1: ...immer To find out if your bulb is dimmable please check the package the bulb itself or call the bulb manufacturer directly CAUTION To Reduce The Risk of Overheating and Possible Damage to Other Equipm...

Страница 2: ...utomation Screw Terminal installation requires wiring connections for Line Hot Load Neutral and Ground Traveler wire required for multi pole installation To change color of the switch 1 Lift the Air G...

Страница 3: ...e Gang Boxes The metal plate surrounding the switch assembly is a heat sink The maximum load rating 600W is provided when installed in a single gang box with the full heat sink Multiple dimmer switche...

Страница 4: ...achment using the enclosure s holes Strip insulation 5 8 16mm UL specifies that the tightening torque for the screws is 14 Kgf cm 12 lbf in SINGLE SWITCH WIRING 1 Shut off power to the circuit at fuse...

Страница 5: ...e primary switch what action to perform b Ground c Neutral 2 DO NOT connect the auxiliary switch to the home s black Hot Line wire Once the switch is properly wired you should be able to use the rocke...

Страница 6: ...meout occurs before the switch has joined the ZigBee network press any button on the switch to resume scanning 3 After the switch is located and paired to the ZigBee network the LED Status Indicator w...

Страница 7: ...riod FCC and IC Compliance U2ZZB3001 The Federal Communication Commission Radio Frequency Interference Statement includes the following paragraph The equipment has been tested and found to comply with...

Страница 8: ...Company Model ZB3001 45857 CAN ICES 3 B NMB 3 B This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause...

Страница 9: ...FLE26 2 DV R40 26W LED Feit PAR30L LEDG5 15W LED Feit G25 DM LED 10W LED Feit PAR20 LEDG5 9 5W LED Utilitech LPAR20 LEDG5 9 5W CFL Ecosmart 40114 SKU 709447 14W LED Philips 3 5E26BA12DBBAAA 3 5W LED M...

Отзывы: