Jasco ZigBee ZB3001 (45857) Скачать руководство пользователя страница 5

10.

 

Connect

 

the

 

white

 

wire

 

to

 

the

 

neutral

 

terminal.

 

Note:

 

UL

 

specifies

 

that

 

the

 

tightening

 

torque

 

for

 

the

 

screws

 

is

 

14

 

Kgf

cm

 

(12

 

lbf

in).

 

11.

 

Insert

 

Switch

 

into

 

the

 

switch

 

box

 

being

 

careful

 

not

 

to

 

pinch

 

or

 

crush

 

wires.

 

12.

 

Secure

 

the

 

switch

 

to

 

the

 

box

 

using

 

the

 

supplied

 

screws.

 

13.

 

Mount

 

the

 

wall

 

plate.

 

14.

 

Reapply

 

power

 

to

 

the

 

circuit

 

at

 

fuse

 

box

 

or

 

circuit

 

breaker

 

and

 

test

 

the

 

system.

 

 

OPTIONAL

 

for

 

THREE

 

or

 

FOUR

WAY

 

CONTROL:

  

 

Connect

 

the

 

Traveler

 

wire

 

(usually

 

Red)

 

to

 

the

 

screw

 

terminal

 

marked

 

TRAVELER

 

on

 

the

 

primary

 

switch

 

(Do

 

Not

 

remove

 

the

 

tape

 

over

 

the

 

terminal

 

if

 

you

 

are

 

not

 

using

 

the

 

traveler

 

connection).The

 

other

 

end

 

of

 

this

 

Traveler

 

wire

 

connects

 

to

 

the

 

TRAVELER

 

screw

 

terminal

 

on

 

the

 

Auxiliary

 

Switch.

 

 

1.

 

The

 

auxiliary

 

requires

 

the

 

following

 

3

 

wiring

 

connections:

 

a.

 

The

 

Traveler

 

wire.

 

This

 

is

 

used

 

to

 

send

 

voltage

 

signals

 

to

 

the

 

primary

 

switch.

 

The

 

signals

 

from

 

the

 

auxiliary

 

tell

 

the

 

primary

 

switch

 

what

 

action

 

to

 

perform.

 

b.

 

Ground.

 

c.

 

Neutral.

 

2.

 

DO

 

NOT

 

connect

 

the

 

auxiliary

 

switch

 

to

 

the

 

home’s

 

black

 

Hot

 

(Line)

 

wire.

 

 

 
 

Once

 

the

 

switch

 

is

 

properly

 

wired,

 

you

 

should

 

be

 

able

 

to

 

use

 

the

 

rocker

 

to

 

manually

 

turn

 

On/Off

 

and

 

dim

 

the

 

connected

 

load

 

 

Basic

 

Operation

 

The

 

connected

 

light

 

can

 

be

 

turned

 

ON/OFF

 

in

 

two

 

ways:

 

1.

 

Manually

 

from

 

the

 

front

 

panel

 

of

 

the

 

in

wall

 

switch

 

2.

 

Remotely

 

with

 

a

 

ZigBee

 

Controller

  

MANUAL

 

CONTROL

 

 

The

 

Front

 

Panel

 

Rocker

 

Switch

 

allows

 

the

 

user

 

to:

 

 

Turn

 

ON/OFF

 

the

 

connected

 

lighting.

 

 

To

 

turn

 

the

 

connected

 

lighting

 

ON:

 

Tap

 

the

 

top

 

of

 

the

 

rocker.

 

 

To

 

turn

 

the

 

connected

 

lighting

 

OFF:

 

Tap

 

the

 

bottom

 

of

 

the

 

rocker.

 

 

To

 

BRIGHTEN/DIM

 

the

 

connected

 

lighting

 

 

To

 

brighten

 

the

 

connected

 

lighting,

 

press

 

and

 

hold

 

the

 

top

 

of

 

the

 

rocker

 

until

 

the

 

desired

 

brightness

 

is

 

achieved

 

 

To

 

dim

 

the

 

connected

 

lighting,

 

press

 

and

 

hold

 

the

 

bottom

 

of

 

the

 

rocker

 

until

 

the

 

desired

 

brightness

 

is

 

achieved

 

 

The

 

dimmer

 

switch

 

retains

 

the

 

previous

 

dimmer

 

setting.

 

When

 

turning

 

the

 

dimmer

 

switch

 

on

 

by

 

tapping

 

the

 

top

 

rocker,

 

the

 

dimmer

 

will

 

automatically

 

return

 

to

 

the

 

previous

 

dim

 

setting.

  

Содержание ZigBee ZB3001 (45857)

Страница 1: ...immer To find out if your bulb is dimmable please check the package the bulb itself or call the bulb manufacturer directly CAUTION To Reduce The Risk of Overheating and Possible Damage to Other Equipm...

Страница 2: ...utomation Screw Terminal installation requires wiring connections for Line Hot Load Neutral and Ground Traveler wire required for multi pole installation To change color of the switch 1 Lift the Air G...

Страница 3: ...e Gang Boxes The metal plate surrounding the switch assembly is a heat sink The maximum load rating 600W is provided when installed in a single gang box with the full heat sink Multiple dimmer switche...

Страница 4: ...achment using the enclosure s holes Strip insulation 5 8 16mm UL specifies that the tightening torque for the screws is 14 Kgf cm 12 lbf in SINGLE SWITCH WIRING 1 Shut off power to the circuit at fuse...

Страница 5: ...e primary switch what action to perform b Ground c Neutral 2 DO NOT connect the auxiliary switch to the home s black Hot Line wire Once the switch is properly wired you should be able to use the rocke...

Страница 6: ...meout occurs before the switch has joined the ZigBee network press any button on the switch to resume scanning 3 After the switch is located and paired to the ZigBee network the LED Status Indicator w...

Страница 7: ...riod FCC and IC Compliance U2ZZB3001 The Federal Communication Commission Radio Frequency Interference Statement includes the following paragraph The equipment has been tested and found to comply with...

Страница 8: ...Company Model ZB3001 45857 CAN ICES 3 B NMB 3 B This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause...

Страница 9: ...FLE26 2 DV R40 26W LED Feit PAR30L LEDG5 15W LED Feit G25 DM LED 10W LED Feit PAR20 LEDG5 9 5W LED Utilitech LPAR20 LEDG5 9 5W CFL Ecosmart 40114 SKU 709447 14W LED Philips 3 5E26BA12DBBAAA 3 5W LED M...

Отзывы: