background image

REMOTE

 

CONTROL

 

ZigBee

 

devices

 

can

 

be

 

controlled

 

directly

 

by

 

your

 

ZigBee

 

Controller

 

and

 

remotely

 

over

 

long

 

distances

 

with

 

a

 

PC

 

or

 

mobile

 

phone

 

app

 

if

 

your

 

home’s

 

controller

 

functions

 

as

 

a

 

gateway

 

connected

 

to

 

an

 

internet

 

router.

  

To

 

control

 

the

 

device

 

remotely

 

it

 

must

 

be

 

paired

 

to

 

the

 

ZigBee

 

Controller

 

as

 

instructed

  

ZigBee

 

Network

 

Pairing

 

Join

 

the

 

switch

 

to

 

the

 

ZigBee

 

Network

 

1. From

 

your

 

ZigBee

 

Controller’s

 

interface,

 

choose

 

to

 

add

 

lighting

 

device

 

and

 

enter

Locating/Pairing

 

mode

 

as

 

instructed

 

by

 

the

 

controller.

2. After

 

applying

 

power

 

to

 

the

 

In

Wall

 

switch,

 

your

 

In

Wall

 

Switch

 

will

 

begin

 

auto

 

scan

 

mode

 

as

 

it

searches

 

for

 

a

 

controller

 

to

 

pair

 

with

Auto

Scan:

 

LED

 

Status

 

Indicator

 

Blinks

 

3x

 

every

 

10

 

seconds

 

as

 

the

 

device

 

scans

 

for

 

a

 

compatible

 

network

 

controller

 

to

 

pair

 

with

 

until

 

Timeout.

 

Timeout:

 

Auto

Scan

 

mode

 

will

 

eventually

 

time

 

out

 

after

 

the

 

LED

 

Status

 

light

 

stops

 

blinking.

 

If

 

device

 

Timeout

 

occurs

 

before

 

the

 

switch

 

has

 

joined

 

the

 

ZigBee

 

network,

 

press

 

any

 

button

 

on

 

the

 

switch

 

to

 

resume

 

scanning.

 

3. After

 

the

 

switch

 

is

 

located

 

and

 

paired

 

to

 

the

 

ZigBee

 

network,

 

the

 

LED

 

Status

 

Indicator

 

will

 

stop

blinking

 

and

 

the

 

switch

 

will

 

appear

 

in

 

your

 

controller’s

 

menu.

 

Setup

 

the

 

switch

 

as

 

an

 

On/Off

control

 

and

 

title

 

the

 

switch

 

in

 

a

 

way

 

that

 

will

 

be

 

easy

 

to

 

identify.

The

 

module

 

is

 

now

 

paired

 

to

 

the

 

ZigBee

 

network

 

and

 

can

 

be

 

controlled

 

remotely.

 

Reset

 

Device

 

(Remove

 

from

 

ZigBee

 

Network)

 

From

 

the

 

ZigBee

 

Controller

 

From

 

your

 

controller

 

or

 

hub

 

interface,

 

choose

 

to

 

remove

 

or

 

delete

 

the

 

lighting

 

device

 

as

 

instructed.

 

The

 

device

 

will

 

be

 

removed

 

from

 

the

 

ZigBee

 

network

 

following

 

indication

 

from

 

your

 

controller.

 

All

 

configuration

 

parameters

 

will

 

be

 

reset

 

after

 

the

 

device

 

is

 

removed

 

from

 

the

 

network.

 

Manual

 

Resetting

 

to

 

factory

 

defaults

 

require

 

t

he

 

user

 

to:

 

1. Lift

 

the

 

air

gap

 

switch

 

at

 

the

 

bottom

 

of

 

the

 

rocker

 

to

 

OFF

 

position

 

to

 

power

 

down

 

the

 

device.

2. Hold

 

down

 

the

 

UP

 

button

3. Push

 

In

 

the

 

air

gap

 

switch

 

to

 

ON

 

position

 

to

 

power

 

up

 

the

 

device.

4. Release

 

UP

 

button

 

within

 

4

 

seconds

 

after

 

power

 

up.

Содержание ZigBee ZB3001 (45857)

Страница 1: ...immer To find out if your bulb is dimmable please check the package the bulb itself or call the bulb manufacturer directly CAUTION To Reduce The Risk of Overheating and Possible Damage to Other Equipm...

Страница 2: ...utomation Screw Terminal installation requires wiring connections for Line Hot Load Neutral and Ground Traveler wire required for multi pole installation To change color of the switch 1 Lift the Air G...

Страница 3: ...e Gang Boxes The metal plate surrounding the switch assembly is a heat sink The maximum load rating 600W is provided when installed in a single gang box with the full heat sink Multiple dimmer switche...

Страница 4: ...achment using the enclosure s holes Strip insulation 5 8 16mm UL specifies that the tightening torque for the screws is 14 Kgf cm 12 lbf in SINGLE SWITCH WIRING 1 Shut off power to the circuit at fuse...

Страница 5: ...e primary switch what action to perform b Ground c Neutral 2 DO NOT connect the auxiliary switch to the home s black Hot Line wire Once the switch is properly wired you should be able to use the rocke...

Страница 6: ...meout occurs before the switch has joined the ZigBee network press any button on the switch to resume scanning 3 After the switch is located and paired to the ZigBee network the LED Status Indicator w...

Страница 7: ...riod FCC and IC Compliance U2ZZB3001 The Federal Communication Commission Radio Frequency Interference Statement includes the following paragraph The equipment has been tested and found to comply with...

Страница 8: ...Company Model ZB3001 45857 CAN ICES 3 B NMB 3 B This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause...

Страница 9: ...FLE26 2 DV R40 26W LED Feit PAR30L LEDG5 15W LED Feit G25 DM LED 10W LED Feit PAR20 LEDG5 9 5W LED Utilitech LPAR20 LEDG5 9 5W CFL Ecosmart 40114 SKU 709447 14W LED Philips 3 5E26BA12DBBAAA 3 5W LED M...

Отзывы: