8

Auxiliary Outputs Information

AUX1 (optional):

 The AUX1 output by default will not be active (open). If 

the user would like to activate this output they must program code: **44 

• 

X *#

 - which controls the AUX1 behavior. The letter X on this code could 

  be substituted by 0, 1, 2 or 3. 

• 

0 = Disabled

 - The AUX1 will stay OPEN.  

• 

1 = Red LED mode

 - The AUX1 will Close when the Red LED turns ON 

  and Open when the Red LED turns “OFF”.  

• 

2 = Green LED mode

 – The AUX1 will Close when the Green LED turns 

  ON and Open when the Green LED turns “OFF”.  

• 

3 = VCC mode

 - The AUX1 will Close when the phone turns ON and 

  Open when the phone turns “OFF”. 

• 

AUX2 (optional):

 The AUX2 output is used for phone line monitoring. 

  When a good phone line is connected to the unit this output is normally 

  open. If the telephone line drops below 2 volts, is disconnected, or 

  shorted for more than 15 minutes, this output will close.  

NOTE:

 AUX2 will only work if the optional 12VAC power supply is 

connected to the P9 connector and a jumper is installed at the LM 

connector on the board. 

Battery and Power Supply Information 

The following information explains how to determine when a battery or 

power supply is needed or when to use a specific type of battery: 

You will need a 9V battery or a 9-24VDC/12VAC power supply with 

8.4V NiMH battery when: 

1.

 The phone drops off the telephone line without completing the call.

2.

 There is more than one phone on the same telephone line and there is 

    a need to call back to a specific elevator phone, or if all elevator

 

    phones need to be “ON” at the same time.

9-24VDC/12VAC Power Supply:

 Can be used on all phone lines. The 

8.4V NiMH battery supplied with the power supply will need to be checked 

every 12 months. An AC connection is required and the battery will be 

charged by the power supply connected to the P9 connector of the board. 

The P9 connector is polarity sensitive so use caution when connecting to 

it (P9 is labeled with + and -).

CAUTION: DO NOT

 use an alkaline or lithium battery when the power 

supply is connected to the P9 connector. 

Содержание PBX

Страница 1: ...red ADA Telephone User s Manual 984 0110 Rev 1 11 20 415 Oser Avenue Suite Q Hauppauge New York 11788 Phone 800 527 9156 Fax 631 864 2631 Email sales us avire global com www januselevator com PBX PNB PSM PSS PSL ...

Страница 2: ...ode Auxiliary Outputs Information Battery and Power Supply Information Troubleshooting Guide Specifications 3 4 5 5 6 7 8 8 9 11 2 If you have questions or problems please call Janus technical support for assistance at 800 527 9156 or visit our website at www avire global com Scan the QR code using your smart phone to connect to our Automated Programming System APS Tel 631 864 4759 ...

Страница 3: ... mounting screws 3 Attach phone line to terminal block at P1 TELCO or the P1A modular phone jack 4 Mount phone screws not provided Surface Mount Style PSM 1 Use mounting plate as a template 2 Attach mounting plate to wall 3 Attach phone line to terminal block at P1 TELCO or the P1A modular phone jack 4 Attach phone cover with screws provided NOTE All style phones are phone line powered If a batter...

Страница 4: ...PC Board Diagram 4 ...

Страница 5: ...button The test will ensure the phone is functioning correctly and as programmed Method B Using the keypad on the board to program it 1 Disconnect the phone line from the P1 connector TELCO or the P1A modular phone jack 2 Connect a 9 volt battery to the battery clips on the board See diagram of phone board 3 Wait 30 seconds and then press the PROGRAM button above the keypad 4 Make sure the red lig...

Страница 6: ...disable the dialer from dialing a phone number Used on a ring down telephone line Enter 94851 or 9000000 and listen for three beeps Enter 0 listen for three beeps enter 1 listen for three beeps Enter 2 listen for three beeps enter 3 listen for three beeps Enter 1180180 listen for three beeps Optional Enter and hang up PURPOSE To Disable the Voice Prompt Message To disable the voice prompt from say...

Страница 7: ...sage 1 XXX Y W Z setup code Default is 1 180 1 8 3 XXX Call Timer 000 060 990 000 Disable timer Y Push Button Control 0 2 0 Push on turn on push again play message 1 Push on turn on push again turn off 2 Push and hold turn on release turn off 3 8 Push and hold to turn on for Y amount of seconds to make a call If pushed for less than Y amount of seconds turn off push again turn off W Unit ID 1 8 Z ...

Страница 8: ...VAC power supply is connected to the P9 connector and a jumper is installed at the LM connector on the board Battery and Power Supply Information The following information explains how to determine when a battery or power supply is needed or when to use a specific type of battery You will need a 9V battery or a 9 24VDC 12VAC power supply with 8 4V NiMH battery when 1 The phone drops off the teleph...

Страница 9: ...m Phone dials incorrect number Possible Cause Check number programmed into phone Plug a phone in the jack and call the same number you are trying to program to see if you can call out Check to see if the phone is on a ring down line Check to see if another auto dialer is on the line and remove it Reprogram unit Problem Low or no sound through the speaker Possible Cause Check speaker connection see...

Страница 10: ...em Phone rings busy Possible Cause Check if other devices are on the line Check where phone line is properly connected to the unit Check voltage on phone line Check polarity on phone line Make sure unit is off Remove our unit from the line to see if line is still busy Problem Phone does not ring Possible Cause Check phone line connection Check ring voltage min 40VAC RMS Check phone line ringing wi...

Страница 11: ... Analog telephone line Optional AC Adapter 9 24VDC 12VAC min 200mA Power Required on hook 0 ma Power Required off hook 20 to 30 ma Phone Line Voltage on hook 24 to 70VDC nominally 48VDC Phone Line Voltage off hook 8 to 20VDC nominally 14VDC Ring Sensitivity 40 120VAC RMS Dialing DTMF Dual Tone Multi Frequency Frequency Response 550Hz 3400Hz 3db Operational Loop impedance 600 ohms FCC Registration ...

Отзывы: