INSTALLATION INSTRUCTIONS
The Pantheon logic controller is designed to
electronically detect and monitor the normal
operation of the door.
This ensures that the operator shall
automatically stop and reverse its closing
motion or alternately stall its opening motion
if an obstruction is detected.
To set the sensitivity adjustment—position
the jumper at
S
and check that the door will
operate without reversing or stalling.
If required move the jumper through the
ranges
M
,
L
&
XL
until satisfactory operation
is achieved.
Final adjustment of the sensitivity setting is
performed by following the instructions as set
out under the heading SENSITVITY
ADJUSTMENT (step 9).
NOTE OF WARNING !!
IT IS ESSENTIAL THAT THIS FEATURE IS NOT RECOGNISED AS AN
EXTERNAL ENTRAPMENT PROTECTION DEVICE AS MAY BE
REQUIRED TO SATISFY NATIONAL SAFETY CODES INCLUDING, BUT
NOT LIMITED TO UL325
STEP 8
.
“Setting the sensitivity adjustment”