50
P113
:
V
/
F minimum voltage
V
/
F minimum voltage setup is relevant to start torque to a certain extend
.
Increasing the value of this parameter properly can increase the torque of
starting
,
it can also cause over current
.
Generally
,
it
'
s not necessary to change
the value of P113
.
P114
:
V
/
F minimum frequency
V
/
F minimum frequency determines the initial point of V
/
F curve
,
it is the
minimum value in V
/
F curve
.
Please refer to the following table for the specific Default setting of each model
:
Model
P107
P108
P111
P115
7
7
15
8
8
8
14
8
9
9
14
8
8
8
27
8
9
9
26
8
10
10
25
8
FC100
-
4T
-
0
.
75G
FC100
-
2S
-
0
.
4G
FC100
-
2S
-
0
.
75G
FC100
-
2S
-
1
.
5G
FC100
-
4T
-
2
.
2G
FC100
-
4T
-
1
.
5G
P115
Carrier frequency
Setting
Range
:
0
-
15
Unit
:
1
Carrier frequency decides the switching frequency of internal power module
.
The
factory setting of inverters with different capacity are different because will affect
motor noise
,
motor heating and disturbance
.
Carrier frequency P115
Motor Noise
Motor Heating
Disturbance
Small
—►
Big
Big
—►
Small
Small
—
Big
Small
—
Big
Therefore
,
when the environment demands running without noise
,
you shall
increase the value of P115
,
the maximum load of inverter will decrease
.
If motor
is far from inverter
,
you shall lower the value of P115 so as to lower the leakage
current between wires and wire to ground
.
When the environment temperature or
motor load is high
,
you shall lower the value of P115 to reduce the heating of the
inverter
.
Refer to table in P114 for the factory set of P115
.
6
Chapter 6 Description of parameter setting
FC100 Series User Manaul
Содержание FC100 Series
Страница 9: ...9 Chapter 2 Storage and Installation ...
Страница 12: ...12 ...
Страница 13: ...13 Chapter 3 Wiring Diagram and Terminal Explanation ...
Страница 20: ...20 ...
Страница 21: ...21 Chapter 4 Keypad Operation ...
Страница 24: ...24 4 ...
Страница 25: ...25 Chapter 5 Function Parameters Table ...
Страница 36: ...36 ...
Страница 37: ...37 Chapter 6 DESCRIPTION OF PARAMETER SETTINGS ...
Страница 99: ...Chapter 7 Maintence and Inspection 99 ...
Страница 108: ...Noise reduction examples 8 108 Chapter 8 Troubleshooting and Fault Informatin FC100 Series User Manaul ...