FEED TIMING
When the presser foot is lowered and the tip of right needle (G) is 2 mm (5/64”) above the
needle plate in its downward motion, the top of the feed dog teeth (H) should be leveled with
the top surface of needle plate (I) at the rearmost position (J).
TO ADJUST
1. Set the stitch length dial at “4” and the differential feed dial at “1.0”.
2. Raise the presser foot and move the needle downward until the tip of the right needle
comes 2 mm (5/64’) above the needle plate. The part (F) of the gauge No. 8289 is 2mm.
3. Lower the presser foot and loosen the 2 screws (C) and adjust the position of the feed
cam (L) while aiming the guide lines (K).
* Turn the feed cam (L) to the direction of (A) if the feed dogs are lower than the surface
of the needle plate (I).
* Turn the feed cam (L) to the direction of (B) if the feed dogs are higher than the surface
of the needle plate (I).
4. Tighten the 2 screws (C) firmly.
16