![Janome 6260QC - Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/janome/6260qc/6260qc_service-manual_633774012.webp)
Adjusting screw
Pull this way
(B)
(A)
Mechanical Adjustment
Needle Thread Tension
The standard tension should be 75 to 90 grams when the tension dial is set at “A” (Auto), measured with a #50 white
polyester thread being pulled at approximately 50 mm/sec.
If the tension is outside the standard range, adjust it as follows.
Adjustment procedure:
1. Remove the face cover.
2. If the thread tension is too tight: Turn the adjusting screw in the direction of (A).
If the thread tension is too loose: Turn the adjusting screw in the direction of (B).
3. Attach the front cover.
10
Содержание 6260QC -
Страница 1: ...SERVICE MANUAL MODEL 6260QC ...