![Janome 6125QC Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/janome/6125qc/6125qc_instruction-book_633769040.webp)
1
3
2
4
(A)
(B)
Adjusting Stretch Stitch Balance
The sewing results of the stretch stitch patterns may
vary depending upon the sewing conditions, such as
sewing speed, type of the fabric, number of layers etc.
Always make test sewing on a scrap piece of the
fabric that you wish to use.
(A) If the pattern is compressed, turn the stretch stitch
balancing dial in the direction of “ + ”.
(B) If the pattern is drawn out, turn the stretch stitch
balancing dial in the direction of “ – ”.
NOTE: In normal sewing, set the dial to the neutral
position, i.e. the groove on the dial is cen-
tered with the standard setting mark.
1.
Stretch stitch balancing dial
2.
Standard setting mark
3.
Groove
4.
Correct shape
1
3
2
4
5
Replacing the Light Bulb
WARNINGS:
Turn off the power before replacing the light bulb.
The bulb could be HOT, wait until it has cooled down
before touching it.
To remove:
Remove the cap and setscrew. Remove the face plate.
Pull out the bulb from the socket.
To Replace:
Insert the bulb into the opening of the socket.
Attach the face plate with the setscrew, and attach the
cap.
1.
Cap
2.
Setscrew
3.
Face plate
4.
Lamp Socket
5.
Light bulb
CARE OF YOUR MACHINE
NOTE: Replace the bulb with the same type rated
12V, 5W. Always refer the part number
#000026002 when ordering a replacement
bulb.