4.  Power Pack Wiring Instructions

  WARNING

When using electrical products, basic precautions 

should always be followed, including the following:

•  DANGER: RISK OF ELECTRIC SHOCK WHICH 

CAN RESULT IN SERIOUS INJURY OR DEATH. 

Before attempting installation or service, ensure 

that all power to the device is disconnected/turned 

off at the circuit breaker. Connect only to a circuit 

protected by a ground-fault circuit-interrupter 

(GFCI).

•  Grounding is required. The unit should be 

serviced by a qualified service representative and 

should be properly grounded and bonded.

•  Install to permit access for servicing.
•  Please read all cautions and safety instructions 

in the Important Safety Instructions section of 

the Jandy AquaPure

®

 Ei

TM

 Series owners manual 

(H0335900 or H0342400). 

Before attempting 

any electrical wiring, be sure to read and 

follow safety instructions. Wiring should only 

be attempted by a qualified professional.

To verify the controller type is set correctly:

1.  Apply power to the power pack. 
2.  Wait for the start-up sequence to complete. 
3.  Press and hold the OUTPUT button for 

approximately four (4) seconds. After four (4) 

seconds, a controller type will be displayed on the 

screen. 

4.  Verify that the JANDY L/M controller type appears 

on the display. If the contoller type is not set to 

JANDY L/M, keep the OUTPUT button pressed to 

toggle through the list of contollers. Each controller 

will be displayed on the screen for two (2) seconds. 

Release the OUTPUT button when JANDY L/M 

appears on the display. 

C.  Wiring to the AquaLink RS Control 

System or PDA

1.  Ensure that all power to the power pack and the 

controller is disconnected/turned off at the circuit 

breaker.  

2.  Remove the screws attaching the cover to the back 

plate and prop the cover up to expose the terminals  

(see Figure 6). 

NOTE:

 Be careful not to pull the ribbon cable that is 

connected to the Power Supply and the Cover. 

A.  Connection to an AquaLink

®

 RS 

Control System or PDA (Optional)

The Jandy AquaLink RS or PDA is a multi-function 

pool controller which can fully control the function 

of the Jandy AquaPure Ei chlorine generating device. 

Adjustment of the chlorine production rate can be 

controlled from the main menu of the Jandy AquaLink 

RS or PDA. The AquaLink RS or PDA offers individual 

pool and spa settings for output percentage.  Refer to 

the AquaLink RS or PDA Owner’s Manual for more 

information.  

NOTE

  The Jandy AquaPure Ei chlorine generating 

device will communicate with all AquaLink 

models Rev. K or later.

B.  Verify the Controller Type on the Power 

Pack is Set Correctly 

Before wiring to an AquaLink RS Control System, 

the controller type must be set to JANDY L/M to 

allow communication between the power pack and the 

AquaLink RS Control System. The default controller 

type setting on the power pack is Jandy L/M. Follow 

the instructions below to verify the controller type is set 

correctly. 

NOTE

  The controller type must be set correctly before 

making the wiring connection between the 

power pack and the AquaLink, otherwise the 

power pack may be locked out of the AquaLink. 

Figure 6. 

Accessing and Wiring to the Power PCB

Cable Tie

Comm Hole