Page 12

2.   It is recommended that the Flow/Temp/Salinity Sensor and Electrolytic Cell be installed in the pool 

return line after the 

fi

 lter and heater.  The Cell can be installed in either a horizontal (as shown in 

Figure 3) or a vertical position.

3.  Position the Flow/Temp/Salinity Sensor and Cell in the recommended position (see page 8 Figure 3, 

page 9 Figures 4 and 5, and page 5 Figure 1).

4.  Locate a suitable section of pipe, approximately 17 inches (432 mm) long or follow the recommended 

plumbing diagrams beginning on page 9, Figures 4 and 5.  The Flow/Temp/Salinity Sensor cable and 
Cell DC cord 

must

 be able to reach from the control center to this section.

6.  Check source voltage.  (All units are factory wired for 240 VAC

).  In order to use on 120 VAC, the 

internal factory wiring of the control center must be changed.  (See wiring diagram page 6 
Figure 2).

7.  Use #12/3 insulated wire and conduit. Wire control center transformer to pool pump power source.  

The control center should be connected to the pump motor switch or automatic timer (Pool Pump 
Timer) as shown in the diagram on page 6 Figure 2.  

The fl ow portion of the Flow/Temp/Salinity 

Sensor is a backup device only.

  Attach the third wire (

Ground

) from the electrical panel to the ground 

point inside the Control Center.  

Earth bonding in Section 3.4 must also be accomplished to ensure 

personal safety and safety of equipment.

3.4  Earth Bonding (Grounding)

A solid, copper # 8 AWG (8.4 mm

2

) wire is 

recommended

 for connecting the control center to a Permanent 

Earth Ground connection that is acceptable to the local inspection authority. Refer to your local codes for 
the acceptable  grounding wire gauge. Attach the bonding point located on bottom of the chassis backplate 
to a Common Earth Bonding Point.  Do not use the AquaPure as the Common Bonding Point.  Each piece 
of non-AquaPure related pool equipment requiring a ground should be bonded to the Common, Approved 
Earth Bonding Point. 

 Never ground pool pump to the chassis backplate

.

3.5  Installing the APURE700 and APURE1400 Cell and Flow/Temp/Salinity Sensor

NOTE:

  Maximum Operating Pressure is 345 kPa or 50 PSI - Minimum Flow Rate is 30 GPM (114 LPM).

1.  Be sure pool pump is turned off.

  WARNING

ATTENTION INSTALLER:  If The Flow/Temp/Salinity Sensor is not installed properly, it may allow the 
Cell to operate without water fl ow.  This would cause a buildup of fl ammable gases which can result 
in FIRE or EXPLOSION.

• 

Mount as shown in Figure 8.  This will result in the most reliable operation.

• 

The Flow/Temp/Salinity Sensor must be mounted:

 

(1) in the same line as the Electrolytic Cell.

 

(2) with no valves or diverters between the Flow/Temp/Salinity Sensor and Cell.

• 

Anytime the Flow/Temp/Salinity Sensor is connected or disconnected and reconnected, the AC 
power to the unit must be turned off and back on (Cycle Power).  If power is not cycled, unreliable 
operation of the Flow/Temp/Salinity Sensor will result.

Содержание AquaPure APURE1400

Страница 1: ...Pending Installation and Operation Manual WARNING FOR YOUR SAFETY This product must be installed and serviced by a professional pool spa service technician The procedures in this manual must be follo...

Страница 2: ......

Страница 3: ...6 Chlorine Testing 18 4 7 Salt NaCl sodium chloride 18 4 7 1 When to Add Salt 18 4 7 2 What Type of Salt to Use 18 4 7 3 How Much Salt to Use 19 4 7 4 How to Add Salt to the Pool 19 Section 5 Operati...

Страница 4: ...Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be res...

Страница 5: ...t can withstand splash out of pool water containing chlorine and or salt and other water purification chemicals All metal components used in and around a pool should be of a high grade quality stainle...

Страница 6: ...ell The AquaPure electrolytic cell contains bipolar electrodes which perform the electrolysis and produce chlorine when energized with DC current Chlorine is generated as pool water containing salt pa...

Страница 7: ...Control ORP External Control Connector AquaLink RS485 Connector External Control ORP External Control Connector AquaLink RS485 Connector CAUTION Factory wired for 240 VAC service If available electric...

Страница 8: ...F approved All Purpose Cleaner Primer An NSF approved All Purpose Cement such as Weld On 794 793 3 2 Plumbing Configurations WARNING When using electrical products basic precautions should always be f...

Страница 9: ...or Orientation with Flow Direction 3 2 1 Recommended Cell and Sensor Orientation Shown below are four different cell and sensor orientations The third port on the cell is designed for installation of...

Страница 10: ...g Figure 3 shows cell and sensor configuration with flow direction Figures 4 and 5 illustrates the recommended plumbing configurations which result in the most reliable operation Note The AquaPure is...

Страница 11: ...on the backplate on the mounting surface Mark screw centers and drill four inch 6 35 mm holes spaced 10 3 8 inches 264 mm on the horizontal center and 6 3 8 inches 162 mm on the vertical center Instal...

Страница 12: ...fety and safety of equipment 3 4 Earth Bonding Grounding A solid copper 8 AWG 8 4 mm2 wire is recommended for connecting the control center to a Permanent Earth Ground connection that is acceptable to...

Страница 13: ...ngth of the electrolytic cell with the full unions is 16 Sensor Port Plug and Nut 2 pvc 2 pvc Figure 8 Flow Temp Salinity Sensor Cell Connector Flow Temp Salinity Sensor or Sometimes Not Covered Tempe...

Страница 14: ...er enclosure 11 Prior to reattaching front cover check the wiring Be sure the Flow Temp Salinity Sensor is plugged in The DC cord should be plugged in Also check the AC wiring CAUTION Do not overtight...

Страница 15: ...the AquaPure from the red 4 pin terminal bar to the AquaLink RS red 4 pin terminal bar see Figure 12 NOTE The screw terminals are removable to aid in installation IMPORTANT Attach the AquaPure wires t...

Страница 16: ...5 m3 capacity 4 2 Determining Pool Size Gallons of Water in Your Pool Rectangular Pools Average length feet x average width feet x average depth feet x 7 5 gallon capacity Circular Pools Diameter feet...

Страница 17: ...Metals some metals can cause loss of chlorine Also metals can stain your pool Have your local pool professional check for metals and recommend methods of removal 4 Chloramines should not be present i...

Страница 18: ...Compare the samples A higher level should be found at the pool return line The higher level at the pool return line indicates the AquaPure is producing chlorine 1 At the pool return line 2 18 inches...

Страница 19: ...alt be inadvertently added to the pool see Section 7 Troubleshooting NOTE To convert gpl grams per liter of a salt solution to PPM Parts Per Million of a salt solution multiply by 1000 i e 3 0 gpl sal...

Страница 20: ...and splash out of pool water containing chlorine and or salt and other water purification chemicals All metal components used in and around a pool should be of a high grade quality stainless steel Car...

Страница 21: ...lbs 132 kg 290 lbs 145 kg 320 lbs 159 kg 350 lbs 172 kg 380 lbs 186 kg 410 lbs 197 kg 435 lbs 210 kg 464 lbs 224 kg 493 lbs 237 kg 522 lbs 250 kg 551 lbs 263 kg 580 lbs 1 50 g l 57 kg 125 lbs 68 kg 1...

Страница 22: ...Salt Concentration Before Addition Salt Addition Required per 1000 gallon pool capacity 0 0 gpl 25 6 lbs 11 6 kg 1 5 gpl 12 8 lbs 5 8 kg 0 3 gpl 23 5 lbs 10 7 kg 1 8 gpl 10 7 lbs 4 8 kg 0 5 gpl 21 4...

Страница 23: ...tment Pressing the arrow button A or arrow button B will change the CHLORINE PRODUCTION in 5 increments Generally adjustments to production should be made in 10 increments Salinity Press the Salinity...

Страница 24: ...PRODUCTION in 5 increments Generally adjustments to production should be made in 10 increments AquaLink RS Power Center Press the Mode Select button to put the AquaLink RS in the Time Out mode Press...

Страница 25: ...rine Salinity Salinity is displayed along with the gpl grams per liter indicator when the Salinity button is depressed If a reading of HH appears the salinity is above 4 5 to 6 5 gpl depending on pool...

Страница 26: ...the desired setting press the Salinity button to confirm the new beeper volume setting The change will be stored in permanent memory If you do not wish to keep the change wait 5 seconds and the chang...

Страница 27: ...ne production 5 4 Startup 5 4 1 Shocking Shocking Super Chlorination is recommended before pool startup Start out with good pool water from the beginning The AquaPure will build up a sufficient level...

Страница 28: ...your manual in a safe place Increase Chlorine Production before party time and return to normal afterwards Increase Chlorine Production when temperature goes up Increase Chlorine Production when numb...

Страница 29: ...of 3 0 3 5 gpl for optimum performance of the AquaPure If additional salt is required follow the procedures and charts described on pages 17 through 20 If salt level does not rise after 24 hours see...

Страница 30: ...oes not need to be cleaned STOP THE CLEANING PROCESS go on to next step e Otherwise allow the cell to remain in the solution until the foaming has stopped However do not leave in acid for more than 1...

Страница 31: ...eeze damage to the Cell and Flow Temp Salinity Sensor by running pump continuously or winterize pool by draining water from pump filter and all intake and return lines Remove the cell clean and store...

Страница 32: ...llow to run for 24 hours Recheck If still too low Super Chlorinate with outside source Take pool water sample to Pool Professional See pages 22 and 25 Low Less than 2 5 gpl salt level in pool water Te...

Страница 33: ...ter cleaning procedures Obstruction in the AquaPure cell Remove cell for inspection Follow cleaning procedures See page 27 Flow Temp Salinity Sensor not installed properly Ensure that the Flow Temp Sa...

Страница 34: ...circuit board Cycle Power Water temperature too low Winterize your pool See page 29 All the above have been checked and indicator light is still on Contact your authorized service representative Prob...

Страница 35: ...rvice representative 171 Possible Backboard service condition Contact an authorized service representative 172 Flow Sensor service condition or flow sensor is unplugged Contact an authorized service r...

Страница 36: ...the digital display 1 Press and hold button D for 15 seconds third beep 2 Within 5 seconds momentarily press C to enter the Fahrenheit Celsius change mode 3 To toggle between Celsius and Fahrenheit pr...

Страница 37: ...URE700 Control Box Cover APURE1400 1 1 3 R0404300 Control Box Decal APURE Top 1 4 R0404400 Control Box Decal APURE Bottom 1 5 R0403900 PCB Front LED All Models Rev B10038 01 1 6 T1005 Transformer 50 6...

Страница 38: ...Screw 6 X 1 2 3 6 1 2 14 R0452300 R0452400 7 Blade Cell 3 Port Cell 14 Blade Cell 3 Port Cell Includes Cell Assy APure O Ring 2 231 DC 16Ft Power Cord Blk 1 3 1 16 R0452500 Port Sensor 3 Port Cell inc...

Страница 39: ...2 1 6 R0403800 Flow Sensor w 16 Cable 1 9 4 2 Port Electrolytic 1 Cell and Sensor Replacement Parts ABS White Unions Dwg Kit Description Qty 1 R0403400 R0403600 2 Port Cell PURE700 w 16 DC Cable 2 Por...

Страница 40: ...mum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals...

Отзывы: